Table 16 - Bard CTHAC181-A Installation Instructions Manual

Outdoor condensing section
Table of Contents

Advertisement

TABLE 16 – CTHAC601
Return Air
Indoor Section
Temperature
75° DB/62° WB
FCP60
80° DB/67° WB
85° DB/72° WB
75° DB/62° WB
CEVA060
80° DB/67° WB
85° DB/72° WB
Low side pressure ± 2 PSIG
High side pressure ± 5 PSIG
Tables are based upon rated CFM (airflow) across the evaporator coil. If there is any doubt as to correct
operation charge being in the system, the charge should be removed, system evacuated, and recharged to
serial plate instructions.
Pressure
75
80
85
Low Side
68
70
High Side
194
211
228
Low Side
73
75
High Side
199
217
235
Low Side
79
81
High Side
207
225
243
Low Side
60
61
High Side
197
210
222
Low Side
64
65
High Side
202
215
228
Low Side
69
70
High Side
209
222
236
90
95
100
105
72
75
77
79
82
246
263
280
298
77
80
82
84
87
252
270
288
305
83
86
88
90
93
261
279
297
315
63
64
65
66
67
235
248
261
273
67
68
70
72
73
241
254
267
280
72
73
75
77
78
250
263
276
289
110
115
84
86
315
332
89
91
323
341
95
97
333
351
68
70
286
299
75
76
293
306
80
81
303
317