Lennox RAVELLE 30 Installation And Operation Instructions Manual

Direct-vent fireplace

Advertisement

Quick Links

P/N 775230M Rev. D 08/2011
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 775230CF.
WHAT'S INSIDE
Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Safety and Your Fireplace . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
FREE Safety Guard Offer
(Protects Against Burns)
Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Attaching the Safety-in-Operation Warnings . . . . . . . . . . . . . . 5
L'information de sûreté importante
[EN FRANÇAIS]
Apposition des mises en garde relatives à la sécurité d'utilisation
Información importante de seguridad
[EN ESPAÑOL]
Colocación de advertencias de seguridad en operación
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases unless a certified kit is used.
WARNING
• HOT GLASS WILL
CAUSE BURNS.
• DO NOT TOUCH GLASS
UNTIL COOLED.
• NEVER ALLOW CHILDREN
TO TOUCH GLASS.
WARNING: If the information in these instructions is
not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the fire
department.
- Installation and service must be performed by a
qualified installer, service agency or the gas supplier.
. . . . . . . . . . . . . 2
. . . . . . . . . . . . 3–4
. . . 5
. . . . . . . . . . . . 3–4
. . . . . . . . . . 5
AVERTISSEMENT
/
• UNE SURFACE VITRÉE CHAUDE PEUT
CAUSER DES BRÛLURES.
• LAISSER REFROIDIR LA SURFACE
VITRÉE AVANT D'Y TOUCHER.
• NE PERMETTEZ JAMAIS À UN ENFANT
DE TOUCHER LA SURFACE VITRÉE.
INSTALLATION AND OPERATION INSTRUCTIONS
Direct-Vent
RAVELLE™ 30
MODELS
Portland
US
OTL Report No. 050-S-12b-5
INSTALLER: Leave this manual
with the appliance.
Wait...
DON'T
THROW
IT AWAY!
This manual contains
important operating
and safety
information.
CONSOMMATEUR : Conservez cette
notice pour consultation ultérieure.
AVERTISSEMENT: Assurez-vous de bien suivre les instruc-
tions données dans cette notice pour réduire au minimum
le risque d'incindie ou d'explosion ou pour éviter tout
dommage matériel, toute blessure ou la mort.
- Ne pas entreposer ni utilizer d'essence ni d'autres vapeurs
ou liquides inflammables dans le voisinage de cet appareil
ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des
téléphones se trouvant dans le bâtiment où vous trouvez.
• Appelez immédiatement votre fournisseur de gaz depuis
un voisin. Suivez les instructions du fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz, appelez
le service des incindies.
- L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
RAVL30
CONSUMER: Retain this manual
for future reference.
INSTALLATEUR : Laissez cette
notice avec l'appareil.
AVISO
/
• EL VIDRIO CALIENTE
CAUSARÁ QUEMADURAS.
• USTED DEBE NUNCA
TOCAR EL VIDRIO CALIENTE.
• LOS NIÑOS DEBEN NUNCA
TOCAR EL VIDRIO.
TM

Advertisement

Table of Contents
loading

Summary of Contents for Lennox RAVELLE 30

  • Page 1 INSTALLATION AND OPERATION INSTRUCTIONS Direct-Vent RAVELLE™ 30 MODELS RAVL30 P/N 775230M Rev. D 08/2011 Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 775230CF. Portland WHAT'S INSIDE Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 OTL Report No.
  • Page 2 To receive your FREE SAFETY GUARD, call 1-800-786-7976 a screen or physical barrier to prevent direct or visit www.lennox.com (Lennox Hearth Products / Owner Resources) contact with the glass . Note: Safety Guards may not be available for some SAFETY GUARD To order a FREE Lennox older models that are no longer in production.
  • Page 3 Toutes les parties de votre foyer ¡Todas las partes de la chimenea Lennox Hearth Products deviennent Lennox Hearth Products se ponen EXTRÊMEMENT CHAUDES ! MUY CALIENTES!  Afin d'éviter de vous brûler gravement ou de  Instale una malla o barrera física para evitar vous blesser, installez une grille ou une barrière...
  • Page 4: Important Safety Information

    Important Safety Information L'information de sûreté importante 1. AVERTISSEMENT. Ne pas utiliser l’appareil si le panneau frontal 1. WARNING: Do not operate appliance with the glass front en verre n’est pas en place, est craqué ou brisé. removed, cracked or broken. 2.
  • Page 5 2 . Si no puede encontrar las etiquetas, sírvase llamar a 2 . If you are unable to locate the labels, please call propriétaire . Lennox Hearth Products o al distribuidor de Lennox Lennox Hearth Products or your nearest Lennox 2 . Si vous ne trouvez pas les étiquettes, veuillez Hearth Products más cercano para recibir etiquetas...
  • Page 6: Appliance Installation

    Appliance Installation, Turn off gas and electrical power to the Warranty Information appliance and allow it to cool before Service, and Maintenance cleaning or servicing the appliance. Notices Your gas appliance is covered by a limited lifetime warranty . You will find a copy of the warranty accompanying this manual .
  • Page 7: General Information

    Any modification une maison préfabriquée (mobile) déjà or alteration may result in damage to Lennox Hearth Products, its employees, installée à demeure si les règlements the appliance or dwelling and will void or any of its representatives assume no locaux le permettent.
  • Page 8: Orifice Size/Altitude Adjustment

    . If there are any questions or if you need further substantiation contact your Lennox Hearth Products dealer . fied service technician . Contact your Lennox Hearth Products dealer for If you have further questions, please contact Lennox Hearth Products .
  • Page 9 (valve and pilot assembly) or installing a conversion kit . Only Lennox Hearth Products conversion kits can be used to Installation Options convert from NG to LP or LP to NG . Contact your Lennox Hearth Products dealer for details . .25Residential .25Vented vertical and horizontal...
  • Page 10: Clearances

    6” (152mm) on the top and 1” (25mm) on the sides and bottom . See Page 22 for The Lennox Hearth Products warranty will be voided if one of the fol- allowable pipe configurations .
  • Page 11 INSTALLATION Framing Dimensions The dimensions given on this page are minimum framing distances necessary to maintain safe clearances between the Ravelle™ 30 gas fireplace and combustible materials . u If the unit is to be vented horizontally with a 90º elbow right off the top of the fireplace and directly through an exterior wall, then a hole 9-1/4”...
  • Page 12 Ravelle™ 30 Fireplace Dimensions 20-3/8” Inches (millimeters) 20.38 (518mm) 7-7/8” 7.90 (201mm) 3-9/16” (91mm) 3.57 9-5/8” 9.63 (245mm) 22” (558mm) 21.97 20-15/16” 28-1/16” 20.94 28.05 (532mm) (713mm) 5” (127mm) 5.01 1-3/8” 11-7/16” (35mm) 1.39 11.45 (291mm) 40-9/16” 40-9/16” (1031mm) 40.59 40.59 (1031mm) 14-1/16”...
  • Page 13 Raised Installations Hearth Extension Considerations The fireplace may be raised by building a platform of sufficient strength to It is IMPORTANT to note that there is a 1” space between the base of the support the fireplace and pipe . When building a raised hearth extension, fireplace and the bottom of the fireplace face .
  • Page 14 The screws should be driven through the cement board into the outer Facing Installation Considerations metal skin of the fireplace . The sheetrock (drywall) is then butted up to the cement board . The sheetrock above the fireplace should also be Non-combustible cement board (such as Wonderboard, Durock, or Har- fastened to the fireplace by driving screws into the outer metal skin of dybacker) must extend 10”...
  • Page 15 C until the holes from which screws A were removed line up may be purchased from your Lennox Hearth Products dealer . Instructions with the lower set of holes . Reinstall screws A and tighten screw B . When for installing the templates are included with the templates .
  • Page 16 Face Installation 2 . Bracket C in the lower diagram is installed on the face during the face assembly (see instructions included with face) . The captive A number of different faces are available for the Ravelle™ 30 gas fireplace, screws D on this bracket should be screwed into captive nuts E on however, all the faces are installed in a similar manner .
  • Page 17: Vertical Terminations

    Vent Parts List VENT INSTALLATION Secure Vent™ direct-vent pipe by Security Chimneys™* may be used with the Ravelle 30 gas fireplace . Please see the lists below to verify the Application: components available from each direct-vent pipe manufacturer . Snorkel terminations are available for applications which may require vertical The Ravelle™...
  • Page 18 Vent Considerations Supports: Horizontal runs of vent must be supported every three feet . Wall straps are available for this purpose . Twist-lock procedure: Four indentations, located on the female ends Pipe Sealing: If Secure Vent™ is used, then sealant is required at only of pipes and fittings, are designed to slide straight onto the male ends the first pipe joint attaching the pipe to the flue collar on the fireplace .
  • Page 19: Clearances

    Horizontal Vent Installation Termination Cap Security Chimneys (Part # SV4CHC) IMPORTANT NOTES: Dura-Vent ® (Part # 984) 1. All Ravelle™ 30 gas fireplaces that are horizontally terminated 9-1/4”x 10-1/4” may only use 6-5/8” x 4” direct-vent pipe by Security Chimneys™ (235mm x 260mm) Framed Hole ®...
  • Page 20 IMPORTANT NOTES: TERMINATION HEIGHTS FOR VENTS ABOVE FLAT OR SLOPED ROOFS 1. All Ravelle™ 30 fireplace vertically terminated may only use 6-5/8” Horizontal Overhang x 4” Secure Vent™ direct-vent pipe by Security Chimneys™ or GS direct-vent pipe by Dura-Vent ® 2 FT Vertical MIN.
  • Page 21 . As such, flue restrictors may need to be installed depending on the vent configuration of your fireplace . The drawings on Page 22 show all the allowable pipe configurations for the Ravelle 30 If the symptoms listed below are present, you may need to adjust the gas fireplace .
  • Page 22 Horizontal Terminations Vertical Terminations The shaded areas in the diagram below show all allowable combinations The diagram to the below shows all allowable combinations of straight of vent configuration with horizontal terminations . Horizontal sections vertical and offset to vertical vent configurations with vertical terminations . of pipe require 1/4”...
  • Page 23: Minimum Clearances

    Exterior Horizontal Vent Termination Clearance Requirements * See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal Termination 18” Ventilated Soffit Inside Corner = 9" in U.S. = 12" in Canada DETAIL D 3 ft.
  • Page 24 5 . The small straight top twig (3021) should be turned so the black flat BRICK PANEL AND LOG SET INSTALLATION end is turned toward the rear . Slide the holes in the bottom of this twig over the right peg on the left front log and the hole on the right front log .
  • Page 25 ELECTRICAL CONNECTIONS * The breaker supplying electricity to the fireplace must be turned off at the electrical panel before any connections are made at the fireplace. * The wire supplying the fireplace should be a minimum of 14 gage and provide 120 Volts at 60 hz. * The fireplace must be grounded in accordance with local electrical codes or, in the absence of local codes, with the National Electrical Code or ANSI/NFPA 70 - latest edition.
  • Page 26: Gas Pressure Requirements

    LP and Natural Gas Supplies This fireplace will not function properly unless the required Your Ravelle 30 gas fireplace is equipped from the factory for use with gas pressure is supplied. See the table on this page for gas natural gas only as specified on the Safety / Listing label attached to the pressure requirements.
  • Page 27 . In the bottom of the the heat output and air movement to different rooms in the house . Ravelle 30 gas fireplace are four inch and six inch (152 mm) diameter knock-out plates . Four inch (102 mm) or six inch (152 mm) diameter Grills: If your Ravelle™...
  • Page 28 2 . Si no puede encontrar las etiquetas, sírvase llamar a anglais . 2 . Si vous ne trouvez pas les étiquettes, veuillez Lennox Hearth Products o al distribuidor de Lennox Cat . No . H8024 Replacement Label Kit appeler Lennox Hearth Products ou votre distribu- Hearth Products más cercano para recibir etiquetas...
  • Page 29 . If you don’t smell gas, go to the next step . 7 . Locate the pilot by looking at the left center of the burner, CAUTION: YOUR LENNOX HEARTH PRODUCTS GAS APPLIANCE under the left elevated log . Blue flame will be seen when the MUST ALWAYS BE OPERATED WITH GLASS IN PLACE.
  • Page 30 10 . After pilot is lit, turn gas control knob counterclockwise WARNINGS to "ON ." Knob can only be turned to "ON" if the knob has popped out . • Improper installation, adjustment, alteration, 11 . To turn burner on, turn "ON/OFF" rocker switch to "ON" or service or maintenance can cause injury or set the thermostat to the desired temperature above room property damage.
  • Page 31 Flame Color and Behavior Air Shutter Adjustment Your Ravelle™ 30 gas fireplace is designed for maximum heating ef- The Ravelle™ 30 gas fireplace has an air shutter control lever located ficiency . Therefore, upon lighting of the main burner the flames will be behind the lower door on the fireplace face and to the left of the gas semi-transparent or “bluish .”...
  • Page 32 Paint Curing Blower Operation Your Ravelle 30 gas fireplace comes equipped with a 155 CFM blower This fireplace has been painted with a high temperature metallic paint . It with a variable speed control and an automatic temperature activated leaves the factory dry to the touch, but completes the curing process as on/off snap switch .
  • Page 33: Millivolt Control System

    Operating Options Thermostat Wire Wire Size Maximum Length Your Ravelle™ 30 gas fireplace comes equipped with an “On/Off” rocker 12 Gage 100 Feet switch used to turn the burner on and off while the pilot light is on . The 14 Gage 64 Feet switch is a round rocker switch located behind the lower door of the...
  • Page 34 2. The viewing glass should be cleaned periodically (see Glass Mainte- MAINTENANCE AND SERVICING nance) . 3. Should repairs or maintenance of the fireplace require the disas- WARNING sembly of the vent/air intake system, the reassembly and resealing should be completed by a qualified service technician and follow the instructions on Page 18 of this manual .
  • Page 35: Fuel Conversion

    . cracked or broken. Glass Replacement: This replacement glass assembly is available from your Lennox Hearth Products dealer . The glass is neo-ceramic and ATTENTION alternative types must not be used . Fuel Conversion Ne pas utiliser l'appareil si le panneau frontal en Converting the Ravelle™...
  • Page 36 TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 37 Contact an Lennox Hearth Products dealer to obtain any of these parts. REPLACEMENT PARTS - RAVELLE™ 30 (RAVL30) Never use substitute materials. Use of non-approved parts can result in poor performance and safety hazards. Part Description Number WARNING H3135 Cassette Assembly NG (if LP, also requires 75204...
  • Page 38 Nail Plates (4x12) galvanized 75382 SCREENF-30 Screen Face/Double Door/Black, Remote Thermostat is not compatible with R30. 37-1/2” W x 25-7/8” H Contact Lennox Hearth Products Technical Dept. with questions. Gas Conversion Kits Barrier Screen Kit (ref. form #506033-23) 75205 RAVL30-CK-LP Conversion Kit, LP to NG (ref.
  • Page 39 MASONRY TEMPLATES (must be used if facing material Aspen exceeds stove body’s built-in Insets (Required - 1” template) Includes 1 Top and (ref. form #775209M) Napa 1 Bottom Inset) Tuscan Cat. No. Model Description (ref. form #775253M) 75206 MT-ARCH30 Arched Cat.
  • Page 40 MODÈLE RAVELLE™ 30 RAVL30 RAVELLE™ 30 section anglophone de cette étiquette Portland Portland FABRIQUÉ PAR: MANUFACTURED BY: LENNOX HEARTH PRODUCTS LENNOX HEARTH PRODUCTS Report No. Número de Rapport PO BOX 987 050-S-12b-5 PO BOX 987 050-S-12b-5 AUBURN, WA., USA 98071 AUBURN, WA., USA 98071...
  • Page 41: For Your Safety Read Before Lighting

    LIGHTING LABEL - ENGLISH FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. • Immediately call your gas supplier from a neighbor’s phone. A.
  • Page 42 LIGHTING LABEL - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort. •...
  • Page 43 NOTES NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
  • Page 44 Fuel Type (Check one) c Natural Gas c Propane Gas (LP) Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products . Consult your local distributor for fireplace code information .

Table of Contents