The SINAMICS V90 drives with the PROFINET interface (referred to as SINAMICS V90 PN) are available in two variants,
400 V variant and 200 V variant.
The 200 V variant is available in three frame sizes: FSB, FSC, and FSD. Frame sizes B, and C are used on the single phase
or three phase power network while frame size D is used on the three phase power network only.
The 400 V variant is available in four frame sizes: FSAA, FSA, FSB, and FSC. All the frame sizes are used on three phase
power network only.
2.1
Deliverables
2.1.1
Drive components
Components in the SINAMICS V90 PN 200 V variant drive package
Component
Illustration
SINAMICS V90 PN,
single/three-phase,
200 V
SINAMICS V90 PN,
three-phase, 200 V
Connectors
Shielding plate
User documentation
Information Guide
Getting Started
A5E37208904-003, 04/2017
Rated power
Outline dimension
(kW)
(Width x Height x
Depth, mm)
0.1/0.2/0.4
55 x 170 x 170
0.75
80 x 170 x 195
1.0/1.5/2.0
95 x 170 x 195
For FSB
For FSC and FSD
For FSB
For FSC and FSD
English-Chinese bilingual version
Frame size
Article number
FSB
6SL3210-5FB10-
1UF0
6SL3210-5FB10-
2UF0
6SL3210-5FB10-
4UF1
FSC
6SL3210-5FB10-
8UF0
FSD
6SL3210-5FB11-
0UF1
6SL3210-5FB11-
5UF0
6SL3210-5FB12-
0UF0
6SL3200-0WT02-
0AA0
6SL3200-0WT03-
0AA0
9