Lubrication Guide - Sullair 3000P User Manual

Industrial air compressor
Hide thumbs Also See for 3000P:
Table of Contents

Advertisement

3000P-4500 USER MANUAL
3.4

LUBRICATION GUIDE

Refer to Figure 3-1 for location of fluid fill port. For
best value and longest uninterrupted service, the
3000-4500 Series compressors are factory filled and
tested with Sullube lubricant.
CAUTION
Mixing of other lubricants within the compres-
sor unit will void all warranties.
If fluid change is required, follow Section 3.6:
Lubrication
Change
Maintenance, Fluid on page 27.
WARNING
"The Plastic Pipe Institute recommends against
the use of thermoplastic pipe to transport com-
pressed air or other compressed gases in
exposed above ground locations, e.g. in
exposed plant piping." (I)
Sullube should not be used with PVC piping
systems. It may affect the bond at cemented
joints. Certain other plastic materials may also
be affected.
(I) Plastic Pipe Institute, Recommendation B,
Adopted January 19, 1972.
Maintenance of all other components is still
recommended as indicated in the Operator's Manual.
DO NOT MIX DIFFERENT TYPES OF FLUIDS.
Contamination of compressor fluid with mineral oil or
other fluids may lead to operational problems such
as foaming, filter plugging, orifice or line plugging.
26
Recommendations
and
NOTE
Flush system when switching lubricant
brands.
When ambient conditions exceed those noted or if
conditions warrant use of "extended" life lubricants
contact Sullair for recommendation.
4
1
2
3
1. Fluid Fill Port
2. Sight Glass
3. Fluid Drain Valve
4. Separator/Sump Tank
Figure 3-1: Fluid Fill Location
3.5
APPLICATION GUIDE
Sullair encourages the user to participate in a fluid
analysis program with the fluid suppliers. This could
result in a fluid change interval differing from that
stated in the manual. Contact your Sullair dealer for
details.
SECTION 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

3700v4500v370045003000pv

Table of Contents