7. Press the Small Coffee button 1 time.
8. Press the Medium Coffee button 2 times. The following is displayed:
1 COFFEE
0
N
IMPULS. 350
9. Observe the numeric value in the lower right corner of the display. It should be
approximately 350.
If a value of "350" is displayed, proceed to Step 14.
If the value is not 350, proceed to Step 10.
10. Press the Small Coffee button 1 time. A blinking box will appear to the right of
the numeric value.
11. Set the value to "350" as follows:
Press the Large Coffee button to increase the value.
Press the Medium Coffee button to decrease the value.
12. Press the Small Coffee button 1 time to store the value.
13. Turn the selector switch to the "Off" position.
14. Turn the selector switch to the "On" or "On with Light" position.
15. Prepare 4 coffees (medium size) one after the other.
16. When the fourth coffee is being dispensed, hold the sensor probe directly in the
flow of coffee. The temperature at the coffee dispenser should be between 171°F
and 194°F.
5.26

Brew Unit Removal (in Start/Home Position)

1. Open the door.
2. Remove the waste container.
3. Hold the handle and press on the part marked PRESS.
4. Gently pull outward on the brew unit to remove it from the appliance.
5.27
Brew Unit Removal (NOT in Start/Home Position)
Warning!
This procedure will remove the brew unit from the appliance without damage.
However, after the brew unit is removed, the drives must be carefully inspected
(and repaired, if necessary), then placed into the start (home) position via service
mode.
1. Before proceeding, close the appliance door, then turn the power on to initiate a
drive reset during the start-up sequence.
2. Once "Ready..." is displayed, open the front door and attempt to remove the brew
unit (see Section 5.26). If the brew unit cannot be easily removed, perform the
following:
3. Open the door.
4. Remove the waste container.
5. Remove the Phillips screw (Figure 5-20, Item 2).
6. Use a small flathead screwdriver to lift up on the locking tab (Figure 5-21).