Installation - Carrier 50XZ024 Installation, Start-Up And Service Instructions Manual

50xz series single-packaged heat pump units with puron (r-410a) refrigerant
Hide thumbs Also See for 50XZ024:
Table of Contents

Advertisement

UNIT
ELECTRICAL CHARACTERISTICS
50XZ042
Not Available At This Time
50XZ048
208/230-1-60, 208/230-3-60
50XZ060
208/230-1-60, 208/230-3-60

INSTALLATION

1. Remove unit from shipping carton. Leave top shipping skid on
the unit as a spreader bar to prevent the rigging straps from
damaging the unit. If the wood skid is not available, use a
spreader bar of sufficient length to protect unit from damage.
2. Position the lifting bracket assembly around the base of the
unit. Be sure the strap does not twist.
UNIT WEIGHT
lb
kg
"
"
463
210
499
226
Fig. 3—50XZ 042-060 Unit Dimensions
4
CENTER OF GRAVITY
UNIT HEIGHT
IN. (MM)
"A"
X
"
"
44.98 (1142.5)
19.5 (495.3)
46.98 (1193.3)
21.0 (533.4)
3. Place each of the 4 metal lifting brackets into the rigging holds
in the composite unit base.
4. Thread lifting bracket strapping around bottom perimeter of
unit as follows:
a. Open lever of tension buckle (ratchet type).
b. Feed strapping through tension buckle as shown in Fig. 8.
c. Pull strapping through tension buckle unit taut.
C00161
IN. (MM)
Y
Z
"
"
17.6 (447.6)
18.0 (457.2)
20.0 (508.0)
17.6 (442.0)