EarthQuake 9800 Series Operator's Manual

Two-man earth auger powerhead
Hide thumbs Also See for 9800 Series:

Advertisement

Operator's Manual
Original Operating Instructions
Two-Man
Earth Auger Powerhead
9800 Series
SN
Includes Model:
9800K
P/N: 22914
ECN: 11558
REV1: 03/10/17
Get parts online at
© 2017 Ardisam, Inc.
www.GetEarthquake.com
All Rights Reserved
READ OM ICON R1

Advertisement

Table of Contents
loading

Summary of Contents for EarthQuake 9800 Series

  • Page 1 Operator’s Manual Original Operating Instructions Two-Man Earth Auger Powerhead 9800 Series Includes Model: 9800K P/N: 22914 ECN: 11558 REV1: 03/10/17 Get parts online at © 2017 Ardisam, Inc. www.GetEarthquake.com All Rights Reserved READ OM ICON R1...
  • Page 2 Two-Man Earth Auger Powerhead 9800 Series INTRODUCTION Thank you for purchasing an Earthquake™ 9800K Powerhead. We have worked to ensure that this powerhead meets the highest standards for usability and durability. With proper care, your powerhead will provide many years of service.
  • Page 3: Warnings And Safety Precautions

    Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series WARNINGS AND SAFETY PRECAUTIONS NOTICE Owner’s Responsibility NOTICE INDICATES YOUR EQUIPMENT CAN BE DAMAGED IF THE SAFETY INSTRUCTIONS THAT Accurate assembly and safe and effective use of the machine is FOLLOW THIS SIGNAL WORD ARE NOT OBEYED.
  • Page 4 Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series General Safety Rules • Never operate machine in wet grass. Always be sure of your footing; keep a firm hold on the handle and walk; • Read, understand, and follow all instructions on the never run.
  • Page 5 Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series DANGER CAUTION ENGINES GIVE OFF CARBON MONOXIDE, AN HOT GASES ARE A NORMAL BY-PRODUCT OF A ODORLESS, COLORLESS, POISONOUS GAS. FUNCTIONING INTERNAL COMBUSTION ENGINE. CARBON MONOXIDE MAY BE PRESENT EVEN IF FOLLOW ALL SAFETY INSTRUCTIONS TO PREVENT YOU DO NOT SMELL OR SEE ANY ENGINE EXHAUST.
  • Page 6 Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series • Carefully inspect the area to be drilled and remove performing powerhead maintenance. • Never run the engine indoors. Exhaust fumes are all foreign objects. Do not drill above underground deadly. water lines, gas lines, electric cables, or pipes. Do not •...
  • Page 7: Safety Decals

    Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series Service • Always stop the engine whenever you leave the equipment, before cleaning, repairing or inspecting the unit. Engine should be turned off and cool. Never make adjustments or repairs with the engine (motor) running. Flip the ON/OFF switch to the OFF position to prevent accidental starting.
  • Page 8: Features

    Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series FEATURES STARTER PULL HANDLE FUEL CAP ON/OFF SWITCH OIL FILL CAP THROTTLE CONTROL AIR FILTER SPARK PLUG MUFFLER SPECIFICATIONS ENGINE TYPE/ PRIMING 4-cycle, 173cc Auto-priming DISPLACEMENT COOLING SYSTEM Forced air cooling FUEL TANK CAPACITY 0.25 gallon...
  • Page 9: Unpacking And Assembly

    Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series OPERATION UNPACKING AND ASSEMBLY Pre-Start Checklist Unpack Powerhead 1. Read and understand the operator's manual that came 1. Carefully lift the powerhead out of the box and remove any packing material. with your unit and the operator's manual that came with the engine.
  • Page 10: Operation

    Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series Filling Fuel Tank WARNING 1. Shut-off engine and allow engine to completely cool before refilling the fuel tank. DO NOT STORE ENGINE INDOORS WITH FUEL IN 2. Move to a well ventilated area, outdoors, away from THE TANK.
  • Page 11 Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series Powerhead Maintenance WARNING 1. Keep all screws, nuts, and bolts tight. DO NOT ATTEMPT TO START ENGINE IN THE 2. For cold weather operation, store the unit in a cool FOLLOWING WAYS: environment.
  • Page 12: Troubleshooting And Repair

    ENGINE OR EQUIPMENT. TEMPERATURE OF MUFFLER AND NEARBY AREAS At Earthquake, we build quality and durability into the design MAY EXCEED 150° F (65° C). AVOID THESE AREAS. of our products; but no amount of careful design by us, and...
  • Page 13: Troubleshooting Guide

    Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series TROUBLESHOOTING GUIDE PROBLEM POSSIBLE CAUSE REMEDY/ACTION Engine will not start 1. Ignition switch off 1. Flip switch to ON position 2. Spark plug wire disconnected 2. Connect spark plug wire to spark plug 3.
  • Page 14: Illustrated Parts Breakdown

    Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series ILLUSTRATED PARTS BREAKDOWN - Powerhead Assembly KEY # PART NO. DESCRIPTION QTY. 60G5NY NUT 5/16-18 NYLOCK KOHLER XT775 VERTICAL ENGINE 67538 NUT 1/4-20 IN NYLOCK 22632 ADAPTER 9800 SERIES 22664 COVER ADAPTER CLUTCH ACCESS...
  • Page 15 Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series ILLUSTRATED PARTS BREAKDOWN - Transmission Assembly 17,18 4,8,13 KEY # PART NO. DESCRIPTION QTY. 9016 CLUTCH DRUM 3 IN THREADED 3004149 SHIM 9800 TRANSMISSION TOP 5,13 8922 BEARING R12 X 3/4 IN ID DOUBLE SEAL...
  • Page 16 Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series ILLUSTRATED PARTS BREAKDOWN - Auger Parts List EA2F, EA3F EA4F EA6F 8, 9 3,22 EA8F EA10F EXT12 3,22 EXT18 Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5...
  • Page 17: Illustrated Parts Breakdown

    Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series ILLUSTRATED PARTS BREAKDOWN - Auger Parts List KEY NO. PART NO. DESCRIPTION QTY. 1423 BOLT-HHCS, 5/16-18 X 2”, GR5 1433 BOLT-HHCS, 3/8-16 X 1-1/2” GR5 22142 SHOCK TOP 1-PC 60G56 NUT-HEX 2-WAY REVERSIBLE LOCK-...
  • Page 18: Warranty

    Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series WARRANTY TERMS AND CONDITIONS Ardisam, Inc. (Ardisam) warrants this powerhead under a five-year limited warranty to be free from defects in the material or workmanship or both for a period not exceeding sixty consecutive months from the date of original purchase by the first retail consumer or first commercial end user.
  • Page 19 Operator’s Manual Two-Man Earth Auger Powerhead 9800 Series NOTES Check for parts online at www.getearthquake.com or call 800-345-6007 M-F 8-5...
  • Page 20 Earthquake®, Division of Ardisam, Inc. 1160 8th Avenue, PO Box 666 Cumberland, WI 54829 800-345-6007 | Fax 715-822-2223 E-mail: info@getearthquake.com All weights, specifications and features are approximate and are subject to change without notice. Due to continuous product improvements, product images may not be exact.

Table of Contents