Daikin ERGA04DAV3A Installer's Reference Manual page 104

Daikin altherma - low temperature split
Hide thumbs Also See for ERGA04DAV3A:
Table of Contents

Advertisement

8/10
Field settings table
Breadcrumb Field code
Setting name
9.I
[4-09]
Which power limitation type is required?
9.I
[4-0A]
Backup heater configuration
9.I
[4-0B]
Automatic cooling/heating changeover hysteresis.
9.I
[4-0D]
Automatic cooling/heating changeover offset.
9.I
[5-00]
Is backup heater operation allowed above equilibrium temperature during space
heating operation?
9.I
[5-01]
What is the equilibrium temperature for the building?
9.I
[5-02]
Space heating priority.
9.I
[5-03]
Space heating priority temperature.
9.I
[5-04]
Set point correction for domestic hot water temperature.
9.I
[5-05]
What is the requested limit for DI1?
9.I
[5-06]
What is the requested limit for DI2?
9.I
[5-07]
What is the requested limit for DI3?
9.I
[5-08]
What is the requested limit for DI4?
9.I
[5-09]
What is the requested limit for DI1?
9.I
[5-0A]
What is the requested limit for DI2?
9.I
[5-0B]
What is the requested limit for DI3?
9.I
[5-0C]
What is the requested limit for DI4?
9.I
[5-0D]
Backup heater voltage
9.I
[5-0E]
--
9.I
[6-00]
The temperature difference determining the heat pump ON temperature.
9.I
[6-01]
The temperature difference determining the heat pump OFF temperature.
9.I
[6-02]
What is the capacity of the booster heater?
9.I
[6-03]
What is the capacity of the backup heater step 1?
9.I
[6-04]
What is the capacity of the backup heater step 2?
9.I
[6-05]
--
9.I
[6-06]
--
9.I
[6-07]
What is the capacity of the bottom plate heater?
9.I
[6-08]
What is the hysteresis to be used in reheat mode?
9.I
[6-09]
--
9.I
[6-0A]
What is the desired comfort storage temperature?
9.I
[6-0B]
What is the desired eco storage temperature?
9.I
[6-0C]
What is the desired reheat temperature?
9.I
[6-0D]
What is the desired DHW production type?
9.I
[6-0E]
What is the maximum temperature setpoint?
9.I
[7-00]
Domestic hot water booster heater overshoot temperature.
9.I
[7-01]
Domestic hot water booster heater hysteresis.
9.I
[7-02]
How many leaving water temperature zones are there?
9.I
[7-03]
--
9.I
[7-04]
--
9.I
[7-05]
Boiler efficiency
9.I
[8-00]
Minimum running time for domestic hot water operation.
9.I
[8-01]
Maximum running time for domestic hot water operation.
9.I
[8-02]
Anti-recycling time.
9.I
[8-03]
Booster heater delay timer.
9.I
[8-04]
Additional running time for the maximum running time.
9.I
[8-05]
Allow modulation of the LWT to control the room temp?
9.I
[8-06]
Leaving water temperature maximum modulation.
Final English - Tanslations in progress
4P495257-1A - 2017.11
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W (*2)
R/O (*1)
(*3)
R/W
R/W
R/W
R/W
R/O (*1)
R/W (*2)
(*3)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
(#) Setting is not applicable for this unit.
Range, step
Default value
0: Current
1: Power
0: 1 (*1)
1: 1/1+2 (*2) (*3)
2: 1/2
3: 1/2 + 1/1+2 in emergency
1~10°C, step: 0,5°C
1°C
1~10°C, step: 0,5°C
3°C
0: Allowed
1: Not allowed
-15~35°C, step: 1°C
0°C
0: Disabled
1: Enabled
-15~35°C, step: 1°C
0°C
0~20°C, step: 1°C
10°C
0~50 A, step: 1 A
50 A
0~50 A, step: 1 A
50 A
0~50 A, step: 1 A
50 A
0~50 A, step: 1 A
50 A
0~20 kW, step: 0,5 kW
20 kW
0~20 kW, step: 0,5 kW
20 kW
0~20 kW, step: 0,5 kW
20 kW
0~20 kW, step: 0,5 kW
20 kW
0: 230V, 1~ (*1) (*2)
1: 230V, 3~ (*2)
2: 400V, 3~ (*3)
1
2~40°C, step: 1°C
25°C
0~10°C, step: 1°C
2°C
0~10kW, step: 0,2kW
3kW
0~10kW, step: 0,2kW
2kW (*2)
3kW (*1)(*3)
0~10kW, step: 0,2kW
0kW (*1)
4kW (*2)
6kW (*3)
0
0
0~200W, step: 10W
0W
2~20°C, step: 1°C
10°C
0
30~[6-0E]°C, step: 1°C
60°C
30~min(50, [6-0E])°C, step: 1°C
45°C
30~min(50, [6-0E])°C, step: 1°C
45°C
0: Reheat only
1: Reheat + sched.
2: Scheduled only
(*4) : 40~75°C, step: 1°C
60°C [E-07]=0
(*4) : 40~80°C, step: 1°C
80°C [E-07]=5
(*5) : 40~60°C, step: 1°C
60°C
0~4°C, step: 1°C
0°C
2~40°C, step: 1°C
2°C
0: 1 LWT zone
1: 2 LWT zones
2.5
0
0: Very high
1: High
2: Medium
3: Low
4: Very low
0~20 min, step 1 min
1 min
5~95 min, step: 5 min
30 min
0~10 hour, step: 0,5 hour
0,5 hour [E-07]=1
3 hour [E-07]≠1
20~95 min, step: 5 min
50 min
0~95 min, step: 5 min
95 min
0: No
1: Yes
0~10°C, step: 1°C
5°C
Installer setting at variance with
default value
Date
Value
(*1) *3V_(*2) *6V_
(*3) *9W_(*4) *HB*_
(*5) EHV*_
(*6) *X*_(*7) *H*