Associations - QUBINO ZMNHDD2 User Manuals

Flush dimmer
Hide thumbs Also See for ZMNHDD2:
Table of Contents

Advertisement

12. Associations

Use associations for direct communication between the Flush Dimmer and other devices within
your Z-Wave network without the need of your primary gateway (hub).
Association Groups:
Root device:
• Group 1: Lifeline group (reserved for communication with the primary gateway (hub)), 1
node allowed.
• Group 2: Basic on/off (status change report for I1 input), up to 16 nodes.
• Group 3: Start level change/stop (status change report for I1 input), up to 16 nodes.
• Group 4: Multilevel set (status change report of the Flush Dimmer) up to 16 nodes
• Group 5: Basic on/off (status change report for I2 input) up to 16 nodes.
• Group 6: Notification report (status change report for I2 input) up to 16 nodes.
• Group 7: Binary sensor (status change report for I2 input) up to 16 nodes.
• Group 8: Basic on/off (status change report for I3 input) up to 16 nodes.
• Group 9: Notification report (status change report for I3 input) up to 16 nodes.
• Group 10: Binary sensor report (status change report for I3 input) up to 16 nodes.
• Group 11: Multilevel sensor report (external temperature sensor report – sensor sold
separately), up to 16 nodes.
End point 1 (Wall Switch I1):
• Group 1: Lifeline group, 0 nodes allowed.
• Group 2: Basic on/off (status change report for I1 input), up to 16 nodes.
• Group 3: Multilevel set (status change report of the Flush Dimmer) up to 16 nodes.
• Group 4: Start level change/stop (status change report for I1 input), up to 16 nodes.
End point 2 (Wall Switch I2):
• Group 1: Lifeline group, 0 nodes allowed.
• Group 2: Basic on/off (status change report for I2 input), up to 16 nodes.
• Group 3: Notification report (status change report for I2 input) up to 16 nodes.
• Group 4: Binary sensor (status change report for I2 input) up to 16 nodes.
End point 3 (Wall Switch I3):
• Group 1: Lifeline group, 0 nodes allowed.
• Group 2: Basic on/off (status change report for I3 input), up to 16 nodes.