Electrical Diagram (110 - 230Vac, 24Vdc) - QUBINO ZMNHDD2 User Manuals

Flush dimmer
Hide thumbs Also See for ZMNHDD2:
Table of Contents

Advertisement

9. Electrical Diagram (110 - 230VAC, 24VDC)

N
Neutral wire (+VDC)
L
Live (line) wire (-VDC)
Output for electrical device
I3
Input for switch/push button or sensor
I2
Input for switch/push button or sensor
I1
Input for push button/switch
TS
Terminal for digital temperature sensor (only for Flush Dimmer device compatible digital
temperature sensor, which must be ordered separately)
S
Service button
WARNING:
The S (Service) button must NOT be used when the device is connected to a 110-230V power
supply.
NOTE: When overload is detected, the device automatically switches off. If this happens, check
if the load matches device specifications and if connections are according to the diagram. To
restore the dimmer to regular operation, please power cycle the device.
Notes for diagram:
43