Download Print this page

Windsor Spirit series Service Manual page 8

Advertisement

WARNING OF
POTENTIAL INJURY
This product contains moving parts.
reduce the risk of injury
To
machine before servicing.
Maintenance and repairs must be done
by qualified personnel ONLY.
CAUTION:
Using non-Windsor parts to repair this
machine will void the 6-3-1 warranty.
8
These procedures are followed at the end of
each work period to extend the life of the
machine.
unplug the
Mai ntenance;
Empty unused cleaning solution by
disconnecting clear hose on back of
machine and pouring into floor drain.
Inspect and clean solution filter screen
inside tank and vac intake screen
inside dome.
Flush the system. Fill solution tank
with 1 or 2 gallons (4
hot water. With machine over floor
drain turn on vac/pump switch until
solution tank is empty.
Inspect spray pattern of jets.
Remove jets and rinse if clogged.
Rinse recovery tank with clean hot
water.
Remove any lint or debris from brush.
Inspect power cord. Remember, this
cord will lay on damp carpet.
Warning:
IMMEDIATELY HAVE WORN OR
FRAYED POWER CORDS
REPLACED.
8.) Inspect hoses. Worn or cracked
hoses may cause loss of vac pressure.
9.)
Place the brush in the storage
position. Press back slightly on the
main handle, press down on the
control knob and turn until the pin
drops into the slot; rotate another
to lock.
For infrequent use or long periods of
storage, flush the system with a neutralizing
solution of I quart (1 liter) white vinegar
mixed with 2 gallons (8 liters) hot water.
Flush the system with clean hot water after
neutralizing.
-
8 liters) of clean