To access the vac motor first remove the solution tank. There are (2) screws which attach the
the motor assembly it will be necessary to remove the
END CAP
6
'
PARTS LIST:
-
-
KEY
PART NO.
DESCRIPTION
39343
Hose, 1.5 x 34" Vac
2
20063
Clamp, 1.75 Worm Gear
Nut, 1/4-20 Nylod<
57047
4
73215
Spacer,
5
14887
Bracket, Vac Motor Mounting
6
70018
Scr, 1/4-20
Nut, 1/4-20 Captive J
7
57082
8
87025
Washer, 1/4 Star
9
70011
53134
53163
1 O C
53 1 83
11
29171
Duct. Vac Coolina Intake
12
87018
Washer, #I0 Flat
Scr 10-32 x
12
14445 115V
14441 240V
operation.
OD x
x

Servicing the Vac Motor

(3)
screws which attach the motor to the
If armature commutator is not concentric,
extremely pitted, or grooved the motor will
need to be replaced or sent to a qualified
service center to restore vac performance.
Wire Terminal
Note:
When replacing carbon vac motor brushes
loosen wire terminal BEFORE removing
screws on bracket.
Important:
These brushes wear
quicker as the length
shortens due to in-
creased heat.
Spring inside brush
housing will damage
motor if brushes are
allowed to wear away
completely.
Periodically check the length of the
carbon brushes.