Scale – One Load Cell
Colour code for load cells used on
Note:
Siemens weighfeeders may be different
than shown. Please refer to the
weighfeeder wiring diagram.
*Where separation between the BW500 and belt scale exceeds 150 m (500 ft.), or legal
for trade certification:
1.
remove the jumpers from BW500 terminal 11/12 and 13/14
2.
run additional conductors from:
BW500 terminal 12 to scale `red'
BW500 terminal 13 to scale `blk'
If the load cell wiring colours vary from those shown, or if extra wires are provided,
consult Siemens.