INSTALLATION SETTINGS
Delay times are summed together when multiple switches are selected (e.g. 2 and 3 = 3 seconds).
There is no delay included if none of these DIP switches are selected.
Notes: 1. THE CHIME CONTACT AND VOLTAGE TRIGGERS ARE IGNORED DURING A CHIME.
2. A TRIGGERED CHIME HAS A SHORT RECYCLE TIME AFTER THE COMPLETION OF PLAYBACk.
DURING THE RECYCLE, NO CHIME WILL PLAY IF A CONTACT CLOSURE IS ACTIVATED.
RECOMMENDED TONE/DELAy SETTINGS
Niles MultiZone System
Niles ZR-4
Niles ZR-6
IntelliControl
®
nIleS aUDIo corPoratIon – 1-800-bUY-HIfI – 1-305-238-4373
(Continued)
Setting the Tone/Delay - Four DIP switches provide a selectable
trigger tone and various delays between when a chime is triggered
and when the chime is actually generated.
Turning switch 1 ON enables a trigger tone that activates the audio
sensing of the Paging Input of a Niles MultiZone System. Switches
2, 3 and 4 ON enable delay times. The delay time provided for each
switch is indicated in the table.
ICS GXR2
Recommended Setting
Tone On (1) no delay
Tone On (1) no delay
Tone On (1) no delay
(continued on next page)