Table B-1. Rsu-5060 Interface Connectors - Comtech EF Data CSAT-5060 Installation And Operation Manual

100 watt c-band transceiver
Table of Contents

Advertisement

100Watt C-Band Transceiver
Redundant Systems
B.2 RSU-5060 I
B.2.1 E
LECTRICAL
The RSU-5060 contains five primary electrical control interface connectors, (J1 through J5) and
six IF signal connectors (J6 through J11) .
Connector
J1
J2
J3
J4
J5
J6
J7
J8
J9
J10
J11
NTERFACES
I
NTERFACE

Table B-1. RSU-5060 Interface Connectors

Function
CSAT Unit A interface
Rx Waveguide Switch interface
CSAT Unit B interface
Tx Waveguide Switch interface
Customer M&C interface
Tx IF Input from Customer Equipment
Tx IF Output to CSAT A
Tx IF Output to CSAT B
Rx IF Output to Customer Equipment
Rx IF Input from CSAT A
Rx IF Input from CSAT B
Connector Type
MS3112E14-19S
MS3112E10-6S
MS3112E14-19S
MS3112E10-6S
MS3112E14-19S
Type N, Female
Type N, Female
Type N, Female
Type N, Female
Type N, Female
Type N, Female
B-2
Revision 0
MN/CSAT5060100.IOM

Advertisement

Table of Contents
loading

Table of Contents