Poulan Pro 115248826 Instruction Manual page 14

Poulan pro trimmer/edger instruction manual
Table of Contents

Advertisement

S Fuel Tank - - Discontinue use of unit if fuel
tank shows signs of damage or leaks.
S Debris Shield - - Discontinue use of unit if
debris shield is damaged.
INSPECT AND CLEAN UNIT AND
DECALS
S After each use, inspect complete unit for
loose or damaged parts. Clean the unit and
decals using a damp cloth with a mild deter-
gent.
S Wipe off unit with a clean dry cloth.
CLEAN AIR FILTER
A dirty air filter decreases engine perform-
ance and increases fuel consumption and
harmful emissions. Always clean after every
5 hours of operation.
1. Clean the cover and the area around it to
keep dirt from falling into the carburetor
chamber when the cover is removed.
2. Loosen bolt with a 5/16 inch (8 mm) socket
wrench. Remove air filter cover and air filter.
NOTE:
To avoid creating a fire hazard or
producing harmful evaporative emissions, do
not clean filter in gasoline or other flammable
solvent.
3. Wash the filter in soap and water.
4. Allow filter to dry.
5. Replace parts.
Air filter
SERVICE AND ADJUSTMENTS
REPLACING THE LINE
For unit to operate properly, the cutting line
should be replaced when line becomes worn to
less than 3 inches (7.5 cm) in length from the
edge of the line exit tunnels on each side of the
cutting head.
1. Remove and discard worn line before
installing new line.
2. Use only 0.115 inch (3 mm) diameter
Poulan PRO brand cut length line.
3. Insert one end of the line through the
positioning tunnel.
4. Continue to feed line through tunnel until
line is centered (leaving equal amounts
on each side). See illustration below.
Positioning
tunnel
INSPECT MUFFLER AND SPARK
ARRESTING SCREEN
WARNING:
uct contains chemicals known to the State of
California to cause cancer.
As your unit is used, carbon deposits build up
on the muffler and spark arresting screen and
must be removed to avoid creating a fire haz-
ard or affecting engine performance.
For normal homeowner use, the muffler and
spark arresting screen will not require any
service. After 50 hours of use, we recom-
mend that your muffler be serviced or re-
placed by an authorized service dealer.
REPLACE SPARK PLUG
Replace the spark plug each year to ensure
the engine starts easier and runs better. In-
spect spark plug every 25 hours of usage.
Clean and/or replace as necessary. Set spark
plug gap at 0.025 inch (0.6 mm). Ignition tim-
ing is fixed and nonadjustable.
NOTE:
with the Canadian standard ICES- -002.
1. Twist, then pull off spark plug boot.
2. Remove spark plug from cylinder and
discard.
3. Replace with Champion RCJ-6Y spark
plug and tighten securely with a 3/4 inch
Air filter cover
(19 mm) socket wrench.
4. Reinstall the spark plug boot.
Bolt
5. Insert ends of line one at a time through
the line exit tunnels.
6. Pull the line and make sure the line is ex-
tended fully through the tunnels.
Line exit
tunnel
7. Correctly installed line will be the same
length on both ends.
REPLACING THE CUTTING HEAD
1. Align hole in the dust cup with the hole in
the side of the gearbox by rotating the
dust cup.
2. Insert a small screwdriver into aligned
holes. This will keep the shaft from turning
while removing and installing trimmer head.
14
The muffler on this prod-
This spark ignition system complies
Line exit
tunnel

Hide quick links: