9.

ELECTRIC CHARACTERISTICS

Model Name
Voltage
Power Supply
Frequency
*1) Max. Operating Current
Starting Current
Main Fuse (Circuit breaker)
Current
*2) Wiring Spec.
Power Cable
*3) Limited wiring length
*1) The maximum current is the total current of indoor unit and outdoor unit.
*2) Wiring Spec.
Selected Sample
(Selected based on Japan Electrotechnical Standard and Codes Committee E00005)
*3) Limited Wiring Length:
This is the wiring length in case voltage descent is less than 2%.
When the wiring length becomes long, please select the wiring of a more larger diameter.
AOU9RL2
V
Hz
A
13.5
A
7.5
A
15
AWG
ft. (m)
- (02 - 11) -
AOU12RL2
115 ~
60
15.0
11.0
20
14
66 (20)