Capacity Compensation Rate For Pipe Length And Height Difference - Fujitsu ASU9RL2 Design & Technical Manual

Hide thumbs Also See for ASU9RL2:
Table of Contents

Advertisement

5.
CAPACITY COMPENSATION RATE FOR PIPE LENGTH
AND HEIGHT DIFFERENCE
MODEL
: AOU9RL2
COOLING
Indoor unit is upper
than outdoor unit.
Height
difference H
Indoor unit is under
than outdoor unit
Indoor unit is upper
than outdoor unit.
Height
difference H
Indoor unit is under
than outdoor unit
Indoor unit
Connection pipe
 1 Indoor unit is upper than outdoor unit.
15m
50ft.
Ú 1
10m
33ft.
7.5m
25ft.
5m
17ft.
0
0ft.
-5m
-17ft.
Ú 2
-7.5m
-25ft.
-10m
-33ft.
-15m
-50t.
HEATING
15m
50ft.
Ú 1
10m
33ft.
7.5m
25ft.
5m
17ft.
0
0ft.
-5m
-17ft.
Ú 2
-7.5m
-25ft.
-10m
-33ft.
-15m
-50t.
Height difference H
H
Outdoor unit
5m
7.5m
17ft.
25ft.
-
-
-
-
-
0.988
1.003
0.992
1.011
1.000
1.011
1.000
-
1.000
-
-
-
-
5m
7.5m
17ft.
25ft.
-
-
-
-
-
1.000
1.014
1.000
1.014
1.000
1.009
0.995
-
0.993
-
-
-
-
Outdoor unit
Connection pipe
 2 Indoor unit is under than outdoor unit.
- (02 - 05) -
Pipe length
10m
15m
33ft.
50ft.
-
0.901
0.969
0.916
0.973
0.919
0.976
0.923
0.984
0.931
0.984
0.931
0.984
0.931
0.984
0.931
-
0.931
Pipe length
10m
15m
33ft.
50ft.
-
0.904
0.976
0.904
0.976
0.904
0.976
0.904
0.976
0.904
0.971
0.900
0.968
0.898
0.966
0.895
-
0.886
H
Indoor unit
20m
67ft.
0.920
0.936
0.939
0.943
0.951
0.951
0.951
0.951
0.951
20m
67ft.
0.898
0.898
0.898
0.898
0.898
0.894
0.892
0.889
0.880

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aou9rl2Asu12rl2Aou12rl2

Table of Contents