Maintenance; Spare Parts - Siemens milltronics Instruction Manual

Mlc belt scale
Hide thumbs Also See for milltronics:
Table of Contents

Advertisement

The tube is designed to move very slightly in its mounting to eliminate mutual
interference between the cells.
2.
Slowly slide it all the way in until it contacts the end of the tube.
Approximately 10 mm (3/8") of the rod should protrude from the tube.
3.
Perform the span calibration as described in the calibration section of the selected
integrator instruction manual.
4.
After the span calibration has been completed, remove the calibrating test rod and
store it in a convenient location.

Maintenance

Because the MLC has no moving parts, the scale requires no active maintenance. Once
the scale is installed into the conveyor, the conveyor becomes part of the total weighing
system. If a problem develops with the conveyor, that problem may also affect the scale.
For this reason, we recommend that a periodic conveyor maintenance program be
established for any conveyor that incorporates a scale.
REMINDER:
when protection of the cells is necessary.

Spare Parts

The only spare part recommended for the MLC is the load cell. Refer to the load cell
nameplate for the proper size and then specify as follows when ordering.
For 10 pound cell: Milltronics Part Number PBD-23900155
For 20 pound cell: Milltronics Part Number PBD-23900156
Idler: Contact your Siemens Milltronics representative. Be prepared to provide
the serial number of the MLC unit.
7ML19985FF01
Milltronics MLC Belt Scale – INSTRUCTION MANUAL
Re-install the shipping stops during maintenance or any other time
Page 9