SERVICE TEST PROGRAM

TUNER
QUARTZ
TEST
TEST
N
TUNER
Button pressed?
Y
Display Tuner Version
"ccc"
N
TUNER
Button pressed?
Y
Service frequencies are
copied to the RAM (see Table1)
Tuner works normally
except:
PROGRAM button
pin 80 of uP = 1,953.125Hz
N
Disconnect
Mains cord ?
Y
Service Mode left
Europe
East Eur.
East Eur. Extended-band
"EAS"
PRESET
"EUR"
"EAS"
1
87.5MHz
87.5MHz
65.81MHz
108MHz
2
108MHz
108MHz
3
531kHz
531kHz
74MHz
87.5MHz
4
1602kHz
1602kHz
5
558kHz
558kHz
531kHz
1602kHz
6
1494kHz
1494kHz
7
153kHz
87.5MHz
558kHz
1494kHz
8
279kHz
87.5MHz
9
198kHz
87.5MHz
98MHz
10
70.01MHz
98MHz
87.5MHz
11
87.5MHz
98MHz
65.81MHz
Table 1
Note: * Depending on the selected grid frequency (9 or 10kHz)
By holding the TUNER and R buttons depressed while switching on the Mains supply, one
of the undermentioned features will be activated:
- the tuning grid frequency is toggled between 9kHz and 10kHz for the Oversea (/21) version.
- the extended FM1 (65.81MHz - 74MHz) is toggled on and off for East Eur. (/34) version.
3-4
To start service test program
hold P & AUX
depressed while
plugging in the mains cord
S refers to Service Mode.
Display shows the
ROM version *
V refers to Version.
"S-Vyy"
(Main menu)
yy refers to Software version number of Processor.
(Counting up from 01 to 99)
N
O
POWER
Button pressed?
Button pressed?
Y
Y
Display shows
Set is in Service PLAY Mode.
32K
Output at (Front Board)
In case of failures, error
pin 80 of uP = 2048Hz
codes according to table 2
will be displayed.
The Service Play Mode is intended to
O
N
detect and identify the failures in the CD Mode.
Button pressed?
In this mode the electronics will still function
even when an error is detected so that
repair activities can be carried out.
Y
Display shows
8M
Output at (Front Board)
9
N
Error code
Button pressed?
E1000
Y
E1001
USA
Oversea
E1002
"USA"
"OSE"
87.5MHz
87.5MHz
108MHz
E1003
108MHz
530kHz
531/530kHz*
1700kHz
1602/1700kHz*
E1005
560kHz
558/560kHz*
1500kHz
1494/1500kHz*
E1006
98MHz
87.5/98MHz*
87.5MHz
87.5MHz
E1007
87.5MHz
87.5MHz
87.5MHz
87.5MHz
E1008
87.5MHz
98/87.5MHz*
E1020
E1070
E1071
E1079
SERVICE
PLAY MODE
N
Figure 1
note 1 : DISC1, DISC3, TUNER, JAZZ, TECHNO and Biplanar (if applicable)
Figure 2
Error Description
Focus Error
Triggered when the focus could not be found within a certain time when starting up the CD
or when the focus is lost for a certain time during play.
Radial Error
Triggered when the radial servo is off-track for a certain time during play.
Sledge In Error
The sledge did not reach its inner position (inner-switch is still close) before approximately
6 Sec. have passed by. Inner-switch or sledge motor problem.
Sledge Out Error
The sledge did not come out of its inner position (inner-switch is still open) before approximately
250 mSec. have passed by. Inner-switch or sledge motor problem.
Jump-offtrack error
Triggered in normal play when the jump destination could not be found within a certain time.
When this error occurred, software will try to recover by initiating the jump command again.
If it is recoverable, the disc will continue to play.
Subcode Error
Triggered when a new subcode was missing for a certain time during play.
PLL Error
The Phase Lock Loop could not lock within a certain time.
Turntable Motor Error
Generated when the CD could not reached 75% of speed during startup within a certain time.
Discmotor problem.
Focus Search Error
The focus point has not been found within a certain time.
The carousel switch is not open within certain time. This can happen when either the switch is
defective and closed all the time, or when the carousel is blocked when located exactly at a
disc position.
The carousel position switch did not close within a certain time. This can happen when the
switch is defective and never closes electrically, or when the carousel is blocked in between
two disc positions. The time-out is approximately 5 Sec.
The drawer could not enter the inside position and is opening again. This happen when the
drawer is blocked and cannot go fully inside or when the drawer switch is defective and does
not close.
Table 2
3-4
DISPLAY
TEST
N
2
Button pressed?
Y
Display shows Fig. 1
and switch all LEDs on
N
2
Button pressed?
Y
Display shows Fig. 2
and selected LEDs on
(see note 1)
9
N
Button pressed?
Y
Various
other Tests
TEST
Activated with
ACTION
R
EEPROM TEST
A test pattern will be sent to the EEPROM.
"PASS" is displayed if the uProcessor read
back the test pattern correctly, otherwise
"ERROR" will be displayed.
9 to Exit
Q
EEPROM FORMAT
Load default data. Display shows "NEW"
for 1 second.
Caution!
All presets from the customer will be lost!!
ENCODER TEST
Volume Knob
Display shows value for 2 seconds.
or
Values increases or decreases in steps of 1
Jog Shuttle knob
until 0 (Min.) or 40 (Max.) is reached.
Disconnect
LEAVE SERVICE
TESTPROGRAM
mains cord

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fw-c280/34Fw-c280/22

Table of Contents