Repeat this procedure as often as needed to reduce the frequency of the weeping
of the P & T Valve. If the weeping persists after following this procedure, you may
elect to install an expansion or accumulator tank in the cold water line between
the tank and check valve to relieve the pressure caused by thermal expansion.
Contact your local dealer for assistance.
REMOVING WATER HEATER
1. Shut off gas supply and disconnect gas supply line from water heater.
2. On all Electric Models, turn off electrical supply then disconnect 120 V.A.C.
supply at junction box mounted on heater.
3. On all DSI Models, disconnect 12 V.D.C. power supply at junction box on heater.
4. Disconnect all wires at module board.
5. Shut off water supply. Drain water from tank following instructions under
"Draining and Storage".
6. Disconnect hot and cold water lines from water heater.
7. Remove screws or nails securing control housing to framed opening.
8. Slide heater out. To reinstall, follow instructions in manual under "Installation
Instructions".
12 V.D.C. ONLY
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE WATER
HEATER MUST BE REPLACED, IT MUST BE REPLACED WITH 18 GA.,
105°C WIRE OR EQUIVALENT.
HI-LIMIT
SWITCH
(GAS)
R
BL
O
LIGHT
JUNCTION
BOX
SWITCH
(
FACTORY WIRING)
(ELECTRIC)
( ---- FIELD WIRING)
DISCONNECT POWER SUPPLY BEFORE SERVICING THERMOSTAT
AND HI-LIMIT UNDER ACCESS COVER.
CAUTION: DO NOT HI-POT (DIELECTRIC HIGH VOLTAGE TEST) THIS
UNIT AFTER INSTALLATION. TO DO SO MAY CAUSE COMPONENT
DAMAGE AND VOIDS WARRANTY OF WATER HEATER.
*12VDC SIDE OF RELAY
120 V.A.C. ONLY
DISCONNECT POWER SUPPLY BEFORE REMOVING COVER
SUBURBAN MANUFACTURING COMPANY, DAYTON, TENNESSEE
120 V.A.C SINGLE PHASE - 1440 WATT ELEMENT - 60 CYCLE
TOTAL CONNECTED WATTS = 1440 - AMPS = 12
BK
BK
*
SWITCH
RELAY
W
GROUNDING SCREW
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE HEATER MUST
BE REPLACED, IT MUST BE REPLACED WITH 14 GA. 105°C WIRE OR
EQUIVALENT.
SI UN DES FILS ELECTIQUES LIVRES AVEC LE CHAUFFE-EAU DOIT
ETRE REMPLACE, UTILISER A CET EFFET UN FIL 14 GA. 105° OU
EQUIVALENT.
*120VAC SIDE OF RELAY
Figure 5
HOT
COLD
MODULE BD.
T'STAT
SPARK CABLE
1 3 4
6
ELECTRODE
R
BR
RELAY
3
1
4
2
GAS VALVE
Y
BR
BROWN
Y
YELLOW
G
GREEN
G
BL
BLUE
R
RED
BK
BLACK
O ORANGE
340539
Figure 4
CODE
BK
W
HI-
LIMIT
T'STAT
BK
BK
BK
ELECTRIC
ELEMENT
340540
Figure 6

PARTS AND SERVICE

Contact a conveniently located recommended Suburban Service Center.
Describe to them the nature of your problem, make an appointment, if necessary,
and provide for delivery of your RV with the appliance installed.
To obtain information on locating a local service agency, contact:
AIRXCEL, Inc., Suburban Division
Customer Service Department
676 Broadway Street
Dayton, TN 37321
(423) 775-2131 Ext. 7101
www.Airxcel.com
GROMMET
(GAS INLET)
BK
SWITCH, LAMP AND PLATE ASSEMBLY
(GAS AND ELECTRIC)
GAS
COLOR
ON
BLACK
WHITE
RESET BUTTON
12 V.D.C. T-STAT
HI-LIMIT
Figure 9
- 7 -
CONTROL HOUSING
ILLUSTRATED SHOWING
INSIDE OF HOUSING
GAS VALVE
CAULK AND SEAL GROMMET (INCLUDING SLIT
AND TUBING) ALL AROUND AIR TIGHT
Figure 7
ELECTRIC
RESET
ON
WATER HEATER
Figure 8
RESET BUTTON
120 V.A.C. T-STAT
HI-LIMIT
Figure 10