The detection range of the human sensor can be checked with the following steps.
(1) If the energy saving function is OFF, press the "SENSOR" button to enable the energy
saving function.
(2) In FAN mode, press the "TEST RUN" button on the remote controller.
The "ECONOMY" indicator fl ashes when the human sensor detects a person.
(3) To fi nish checking the detection range, push the "Start/Stop(
operation.

11. TEST RUN

Check items
(1) Is operation of each button on the remote control unit normal?
(2) Does each lamp light normally?
(3) Do air fl ow direction louvers operate normally?
(4) Is the drain normal?
(5) Do not have an abnormal noise and vibration during operation?
 Do not operate the air conditioner in test run for a long time.
[Operation method]
Before starting the test run, wait for 1 minute after connecting the power supply.
By the wireless remote controller
 To start the test run, press the "Start/Stop(
remote controller with a by using the tip of a ballpoint pen or other small object.
By the indoor unit
 To start the test run, keep on pressing the indoor unit button for more than 10 seconds.
 To end test operation, press the remote controller "Start/Stop(
(When the air conditioner is running by pressing the "TEST RUN" button, the
"OPERATION" Lamp and "TIMER" Lamp will simultaneously fl ash slowly.)

12. REMOTE CONTROLLER INSTALLATION

Check that the indoor unit correctly receives the signal from the remote controller, then
install the remote controller holder.
Do not install the remote controller holder in the following conditions:
• Any places exposed in direct sunlight
• Positions affected by the heat from a stove or heater
12.1. Remote controller holder installation
 Install the remote controller a maximum distance of 7 m from the remote control signal
receiver. After installing the remote controller, check that it operates correctly.
 Install the remote controller holder to a wall, pillar, etc. with the tapping screw.
Remote controller
holder fi xing
Remote controller
holder
Tapping
screw
(small)

13. SELECTING THE REMOTE CONTROLLER CUSTOM CODE

When two or more air conditioners are installed in a room and the remote controller is
operating an air conditioner other than the one you wish to set, change the custom code
of the remote controller to operate only the air conditioner you wish to set (4 selections
possible).
When two or more air conditioners are installed in a room, please contact your retailer to
set the individual air conditioner custom codes.
Selecting the Remote Controller Custom Code
Use the following steps to select the custom code of the remote controller. (Note that the
air conditioner cannot receive a signal if the air conditioner has not been set for the match-
ing custom code.)
(1) Press the "Start/Stop(
)" button until only the clock is
displayed on the remote controller display.
(2) Press the "MODE" button for at least 5 seconds to dis-
play the current custom code (initially set to A).
(3) Press the "TEMP." (
/
) buttons to change the cus-
tom code between A→B→C→D.
Match the code on the display to the air conditioner
custom code.
(4) Press the "MODE" button again to return to the clock
display. The custom code will be changed.
• If no buttons are pressed within 30 seconds after the custom code is displayed, the
system returns to the original clock display. In this case, start again from step 1.
• The air conditioner custom code is set to A prior to shipment.
)" button and stop the
)" button, the "TEST RUN" button on the
)" button.
CAUTION
Remote controller
mounting
(1) Set
Remote
controller
(2) Down

14. FUNCTION SETTING

Perform the "FUNCTION SETTING" according to the installation conditions using the
remote controller.
• Confi rm whether the wiring work for outdoor unit has been fi nished.
• Confi rm that the cover for the electrical enclosure on the outdoor unit is in place.
• This procedure changes to the function settings used to control the indoor unit
according to the installation conditions. Incorrect settings can cause the indoor unit to
malfunction.
• After the power is turned on, perform the "FUNCTION SETTING" according to the
installation conditions using the remote controller.
• The settings may be selected between the following two: Function Number or Setting
Value.
• Settings will not be changed if invalid numbers or setting values are selected.
Selecting the Function Number and Setting Value
(1) While pressing the "POWERFUL" button and "TEMP." (
press the "RESET" button to enter the function setting mode.
(2) Press the "10°C HEAT" button.
(3) Press the "TEMP." (
/
) buttons to select the function number. (Press the "10°C
HEAT" button to switch between the left and right digits.)
(4) Press the "POWERFUL" button to proceed to setting value. (Press the "POWERFUL"
button again to return to the function number selection.)
(5) Press the "TEMP." (
/
) buttons to select the setting value. (Press the "10°C
HEAT" button to switch between the left and right digits.)
(6) Press the "MODE" button once. Please confi rm the beeping sound.
(7) Next, please press "Start/Stop(
confi rm the beeping sound.
(8) Press the "RESET" button to cancel the function setting mode.
(9) After completing the FUNCTION SETTING, be sure to disconnect the power supply
and then reconnect it.
After disconnecting the power supply, wait 30 seconds or more before reconnecting it.
The function setting will not become active unless the power supply is disconnected
and then reconnected.
Filter clean operation interval
Select appropriate intervals for automatically cleaning the air fi lter according to environmental
conditions and the conditions of use.
Setting Description
Standard (40 hours)
Long interval (64 hours)
Short interval (24 hours)
Filter cleaning disabled *
* You can use the "FILTER CLEAN" button to clean the fi lter manually.
Left/right swing operation range
Select the operation range of the left/right swing according to the installation condition.
Setting Description
Standard
Left  Right
Left side
Left Slightly right
Right side
Slightly left Right
CAUTION
) button simultaneously,
Function Number
Setting Value
)" button once to fi x the function setting. Please
CAUTION
(♦... Factory setting)
Function
Setting Value
Number
00
01
10
02
03
(♦... Factory setting)
Function
Setting Value
Number
00
24
01
02
En-11