14
en | Installation
Figure 5.5: Wire knockout locations
Callout ᅳ Description
1 ᅳ Surface wiring knockout, motion detector's left side
2 ᅳ Through- wall wiring knockout
3 ᅳ Surface wiring knockout, motion detector's right side
4 ᅳ Through a B328 bracket wiring knockout*
* If you use the bracket mount knockout for wires, run the wires between the walls marked
in red in the figure. With the wiring between the walls and behind the terminal block, other
features, such as EOL resistor jumper pins, cannot interfere with or puncture the wires.
5.4

Bubble level

The motion detector's coverage pattern performs optimally when mounted vertically. The
motion detector base includes a removable bubble level which helps you align the unit. Before
drilling the mounting holes in the surface, use the bubble level to align the motion detector.
Figure 5.6: Leveling the detector