Curtis G3 User Manual

Digital sweet tea brewing system with rotating brew basket
Hide thumbs Also See for G3:

Advertisement

Quick Links

G3 Digital Sweet Tea Brewing System
with Rotating Brew Basket
: Please leave this booklet with the machine.
022317A
FC14 - RSTB, FRONT COVER
F-10013 revA

Advertisement

Table of Contents
loading

Summary of Contents for Curtis G3

  • Page 1 G3 Digital Sweet Tea Brewing System with Rotating Brew Basket : Please leave this booklet with the machine. 022317A FC14 - RSTB, FRONT COVER F-10013 revA...
  • Page 2: Table Of Contents

    ................................................................................................................................................EC4 ..............................Contact Information Wilbur Curtis Co., Inc. 6913 Acco Street | Montebello, CA 90640 US Phone: 323-837-2300 | Toll Free: 800-421-6150 Email: csrassistance@wilburcurtis.com | Web: www.wilburcurtis.com . - 4:00 . PT Email: techsupport@wilburcurtis.com RSTB, CONTENTS LIST...
  • Page 3: Fs14

    KEY FEATURES/SPECIFICATIONS/SYSTEM REQUIREMENTS FS14 Key Features • • • • • MODEL # DESCRIPTION PHASE VOLTS AMPS HEATING CONFIG WIRE WATTS HERTZ GAL/HR Sweet Tea Brewing System wit Rotating Brew RSTB 1 PH 120 V 13.8 A 1 X 1600 W 2W + G 1650 W 50/60 Hz...
  • Page 4: Is2

    INSTRUCTIONS could result in personal injury or void the warranty. • This appliance is designed for commercial use. Any service other than cleaning and preventive maintenance should be performed by an authorized Wilbur Curtis service technician. • serviceable parts inside.
  • Page 5 IMPORTANT SAFEGUARDS CE Requirements • This appliance must be installed in locations where it can be overseen by trained personnel. • • • • This appliance must not be cleaned by water jet. • instruction concerning use of the appliance in a safe way and if they understand the hazards involved. •...
  • Page 6: Ii2

    INSTALLATION INSTRUCTIONS WARNING: WARNING: properly grounded. NOTICE: SPECIFICATIONS section. IMPORTANT: Installation Instructions Installation Requirements • A secure surface capable of supporting the weight of the appliance. • For units without an attached cord set: Appropriately sized, UL listed, grounding type power cable to meet enough •...
  • Page 7: Ii8

    INSTALLATION INSTRUCTIONS Installation Leveling WARNING: Use the leveling legs to level the brewer only. Do not use them to adjust brewer height. Do not extend them higher than necessary. Position the brewer on the counter top. Level it left to right and front to back by turning the bottom of the legs.
  • Page 8 INSTALLATION INSTRUCTIONS Connect the Brewer Wiring (cont.) Brewers With A Cord Set Attached 12 Connect the power cord to the appropriate electrical outlet. WARNING: Connect the power cord to the appropriate type and size electrical outlet. If the electrical outlet is not compatible with the power cord, have it upgraded by a licensed electrician.
  • Page 9: Oi9

    Do not remove the brew basket while “Brewing” appears on the display. WARNING - DO NOT refrigerate unused tea overnight for later consumption. The G3 Tea Brewer is factory preset for optimal performance. DISPENSER The brewer should be ON.
  • Page 10: Oi14

    OPERATING INSTRUCTIONS OI14 Sweetener Bag-in-Box BIB Replacement/Connection Instructions The sweet tea mixing system is designed to provide continuous operation, provided that two BIBs are always connected. When one BIB becomes empty, the system automatically switches over to the other one. Replace empty BIBs immediately to assure continuous operation.
  • Page 11: Ci1

    CLEANING INSTRUCTIONS WARNING: HOT SURFACES - To avoid injury, allow the brewer and dispenser(s) to cool before cleaning. NOTICE - Do not use cleaning liquids, compounds or powders containing chlorine (bleach) or corrosives. USE OF THESE PRODUCTS WILL VOID THE WARRANTY. Cleaning The Brewer - Daily WARNING: DO NOT immerse the brewer in water or any other liquid.
  • Page 12: Ci8

    CLEANING INSTRUCTIONS Sweet Tea Mixing System Cleaning and Sanitizing (Weekly) The brewer pours sweetener into the tea dispenser at the end of the brew cycle. Setting the brewer to Fast Brew can speed up this cleaning procedure (see the PROGRAMMING GUIDE to turn on Fast Brew). Use a concentrated cleaning solution to simplify the cleaning procedure.
  • Page 13: Ci6

    CLEANING INSTRUCTIONS Cleaning the Tea Dispenser (Daily) Cleaning the Container Prepare a mild solution of detergent and warm water. Remove the dispenser from the brewer and remove the lid. Rinse. Wash - Wipe the exterior surfaces with a sponge and the detergent solution to remove spills and debris.
  • Page 14 PROGRAMMING GUIDE Curtis To enter programming mode: With unit OFF, press and hold bottom right BREW button (4). Then press and release Entering ON/OFF button. Continue to Programming mode hold down BREW button until Enter Code Enter Code appears. - - - - Enter 4 digit code.
  • Page 15 PROGRAMMING GUIDE Programming Options To exit, press until Exit appears on the display, then press Tea Recipes - sets the tea recipe. Press to access. Press to choose from standard-gray, standard- purple, Standard-Amber, Tropical-Gray, Tropical-Purple, 76/308-Gray or 76/308-Purple. Press to save and exit programming mode.
  • Page 16 PROGRAMMING GUIDE Tea Half Batch - turns half batch On and Off. Once accessed ( ), press to toggle between On and Off. Press to save. Press to display the subsequent menu features. Tea Drip-Out - sets the Tea Drip-Out time. Drip-out allows additional time for tea to drain from the brew basket before “Brewing”...
  • Page 17 PROGRAMMING GUIDE Coffee PulseBrew (combo units only) - selects the Coffee Pulse Brew pattern (Pre-Infusion must be Off to press the BREW button for which Pulse Brew needs to be changed. Press to select the desired setting (see guidelines below for information on various settings). Press to save.
  • Page 18 PROGRAMMING GUIDE Master Reset - resets the brewer universal control module (UCM) to the factory default settings. Once accessed ( ), “Are You Sure?” will appear on the display. Press for Yes or for No. If you press No, the display goes back to the programming menu.
  • Page 19 ROUGH-IN DRAWINGS RD17 RSTB - Sweet Tea Brewer 16.61 in 9.11 in [42.2 cm] [23.1 cm] 34.20 in [86.9 cm] 22.87 in 22.61 in [58.1 cm] [57.4 cm] 13.41 i n 11.92in [34.1 cm] [30.3 cm] 1.20 i n 13.09 in I.D. 20.84 i n [3.0 cm] [33.2 cm]...
  • Page 20 ILLUSTRATED PARTS/RECOMMENDED PARTS IP14 Supplies and Accessories - All Models WC-29025 - Spray Head CAB-1 - Cleaning Brush (Purple) Sold by the case RSTB - Main Chassis - Exploded View See section IP21...
  • Page 21: Ip14

    COVER, TOP ALPGT/D500GT/D60GT TLP/TCTS/ WC-29044 SLEEVE, OVERFLOW ASSY GEN USE WC-58117 CBS/GEMSS WC-800 VALVE, TRANSFER FLOJET SWEET TEA LABEL, UCM OVERLAY RSTB 1BATCH CURTIS WC-390159 WC-2707 TEE, FLARE ¼ x ¼ x 3/8 BRASS LOGO WC-53038 TUBE ASSY, FLEXIBLE 1/4 FLARE 11-1/8”...
  • Page 22: Ip21

    ILLUSTRATED PARTS/RECOMMENDED PARTS IP21 WC-6277/WC-75236 - Tank Assembly WC-6277/WC-75236 - Tank Assembly - Parts List ITEM # PART # DESCRIPTION ITEM # PART # DESCRIPTION TANK, COMPLETE 1600W 120V D500GT/TCTS/ GUARD, SHOCK/HEATING ELEMENT FOR SINGLE WC-6277 WC-4394 PTT/CBS HEATING ELEMENT TANK, ASSY D500GT/H/TCTS/PTT3/ CBS W/WC- THERMOSTAT, MANUAL RESET 120/ 240 VAC 25A WC-75236...
  • Page 23 ELECTRICAL SCHEMATICS ES17 RSTB - 120 Volts RSTB, ELECTRICAL SCHEMATIC 091516NC...
  • Page 24 TROUBLESHOOTING GUIDE WARNING: Electric Shock Hazard - Scald and Burn Hazard - IMPORTANT: always check all Valve Test Procedure Troubleshooting Guidelines • • • • Valve Test Procedure in either direction Water Not Hot Enough replace the temperature sensor Water Heats More Slowly Than Usual...
  • Page 25 If the UCM is operating normally, check for a false over-temp error caused by the temperature sensor. Check the resistance across the leads of the temperature sensor. If the resistance is less than 10 k when the water is cool, replace the temperature sensor. G3 BREWERS WITH TRIAC, TROUBLESHOOTING GUIDE 042017A...
  • Page 26 If power is not being supplied to the pump, check the wiring to the pump, then check for proper pump output power from the UPM (on G4 models) or the UCM (on G3 models). SWEET TEA BREWER PUMP, TROUBLESHOOTING GUIDE...
  • Page 27: Ec4

    ERROR CODES System Fault Messages An error message will appear on the screen in the event of a malfunction under the following conditions: ERROR MESSAGE WARNING DESCRIPTION CAUSE Water Level Error G3 BREWER, ERROR CODES 042017A...
  • Page 28 Return Merchandise Authorization (RMA): All returned equipment must be properly re-packaged in the original carton and received by Curtis within 45 days following the issuance of a RMA. NO UNITS OR PARTS WILL BE ACCEPTED WITHOUT A RETURN MERCHANDISE AUTHORIZATION (RMA).

This manual is also suitable for:

RstbRstba10000-001

Table of Contents