Fr-Cv-(H) Power Regeneration Common Converter - Mitsubishi Electric MR-J4-10A(-RJ) Instruction Manual

General-purpose ac servo melservo-j4 general-purpose interface mr-j4 series servo amplifier
Hide thumbs Also See for MR-J4-10A(-RJ):
Table of Contents

Advertisement

11. OPTIONS AND PERIPHERAL EQUIPMENT

11.5 FR-CV-(H) power regeneration common converter

When using the FR-CV-(H) power regeneration common converter, set [Pr. PA02] to "_ _ 0 1" and set [Pr.
PC27] to "_ _ _ 1".
11.5.1 Model designation
The following describes what each block of a model name indicates. Not all combinations of the symbols are
available.
POINT
For details of the power regeneration common converter FR-CV-(H), refer to the
FR-CV Installation Guide (IB(NA)0600075).
Do not supply power to the main circuit power supply terminals (L1/L2/L3) of the
servo amplifier. Otherwise, the servo amplifier and FR-CV-(H) will malfunction.
Connect the DC power supply between the FR-CV-(H) and servo amplifier with
correct polarity. Connection with incorrect polarity will fail the FR-CV-(H) and
servo amplifier.
Two or more FR-CV-(H)'s cannot be installed to improve regeneration capability.
Two or more FR-CV-(H)'s cannot be connected to the same DC power supply
line.
When using FR-CV-(H), set [Pr. PA04] to "0 0 _ _" to enable EM1 (Forced stop
1).
F
R
-
C
V
-
H
7 .
5
K
Capacity
Symbol
Capacity [kW]
7.5K
7.5
11K
11
15K
15
22K
22
30K
30
37K
37
55K
55
Symbol
Voltage class
None
200 V class
H
400 V class
11 - 42