HP ProLiant ML110 Generation 6 (G6) Quickspecs page 10

Table of Contents

Advertisement

QuickSpecs
Models
SATA Models
SATA Models
SATA Models
SATA Models
NOTE: HP NHP Internal SAS/SATA 4 port cable kit (487734-B21) is required when Smart Array Controller is ordered with a BTO
NOTE:
NOTE:
NOTE:
configuration
NOTE:
NOTE:
NOTE: For general information about HP Smart Array B110i SATA RAID Controller, go to:
NOTE:
http://h18004.www1.hp.com/products/servers/proliantstorage/arraycontrollers/smartarrayb110i/index.html
Entry Model
Entry Model
Entry Model
Entry Model
HP ML110 G6 G6950
HP ML110 G6 G6950
HP ML110 G6 G6950
HP ML110 G6 G6950
NHP SATA Server
NHP SATA Server
NHP SATA Server
NHP SATA Server
506666-xx1
Base Model
Base Model
Base Model
Base Model
HP ML110 G6 X3430
HP ML110 G6 X3430
HP ML110 G6 X3430
HP ML110 G6 X3430
NHP SATA Server
NHP SATA Server
NHP SATA Server
NHP SATA Server
506667-xx1
Processor
Processor
Processor
Processor
Cache Memory
Cache Memory
Cache Memory
Cache Memory
Memory
Memory
Memory
Memory
Storage Controller
Storage Controller
Storage Controller
Storage Controller
Hard Drive
Hard Drive
Hard Drive
Hard Drive
Internal Storage
Internal Storage
Internal Storage
Internal Storage
Power Supply
Power Supply
Power Supply
Power Supply
Networking
Networking
Networking
Networking
Management
Management
Management
Management
Optical Drive
Optical Drive
Optical Drive
Optical Drive
Mouse & Keyboard
Mouse & Keyboard
Mouse & Keyboard
Mouse & Keyboard
Form Factor
Form Factor
Form Factor
Form Factor
Processor
Processor
Processor
Processor
Cache Memory
Cache Memory
Cache Memory
Cache Memory
Memory
Memory
Memory
Memory
Storage Controller
Storage Controller
Storage Controller
Storage Controller
Hard Drive
Hard Drive
Hard Drive
Hard Drive
Internal Storage
Internal Storage
Internal Storage
Internal Storage
Power Supply
Power Supply
Power Supply
Power Supply
Networking
Networking
Networking
Networking
Management
Management
Management
Management
Optical Drive
Optical Drive
Optical Drive
Optical Drive
Mouse & Keyboard
Mouse & Keyboard
Mouse & Keyboard
Mouse & Keyboard
Form Factor
Form Factor
Form Factor
Form Factor
DA - 13477
(1) Intel® Pentium® processor G6950 (2.80GHz, 73W, 3MB, 1066)
3MB Intel® Smart Cache
2GB (1x2GB) PC3-10600E DDR3 UB ECC
HP Embedded 6 Port SATA Controller (4 ports for HDD)
HP Embedded Smart Array B110i SATA RAID Controller (RAID 0/1/10)
1 x 160GB Non-hot-plug LFF SATA
4.0TB (4 x 1.0TB) Non-hot plug LFF SATA (Maximum)
300W Non-Hot Plug, Non-Redundant Power Supply (80% efficiency)
Embedded NC107i PCI Express Gigabit Ethernet Server Adapter
Integrated HP ProLiant 100 G6 Lights Out 100i Remote Management
HP Half-Height 16x SATA DVD-ROM
None ships standard
Micro ATX Tower (4U)
(1) Intel® Xeon® processor X3430 (2.40GHz, 95W, 8MB, 1333, Turbo
1/1/2/3)
8MB Intel® Smart Cache
2GB (1x2GB) PC3-10600E DDR3 UB ECC
HP Embedded 6 Port SATA Controller (4 ports for HDD)
HP Embedded Smart Array B110i SATA RAID Controller (RAID 0/1/10)
1 x 250GB Non-hot-plug LFF SATA
4.0TB (4 x 1.0TB) Non-hot plug LFF SATA (Maximum)
300W Non-Hot Plug, Non-Redundant Power Supply (80% efficiency)
Embedded NC107i PCI Express Gigabit Ethernet Server Adapter
Integrated HP ProLiant 100 G6 Lights Out 100i Remote Management
HP Half-Height 16x SATA DVD-ROM
None ships standard
Micro ATX Tower (4U)
Worldwide — Version 6 — May 6, 2010
HP ProLiant ML110 Generation 6 (G6)
HP ProLiant ML110 Generation 6 (G6)
HP ProLiant ML110 Generation 6 (G6)
HP ProLiant ML110 Generation 6 (G6)
Page 10

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents