Before Each Start-Up:
1.
Place On/Auto/Off lever to
"OFF".
2.
Turn the regulator knob counter-
clockwise to set the outlet
pressure to zero.
3.
Attach hose and accessories.
NOTE: The hose or accessory will
require a quick connect plug if the air
outlet is equipped with a quick
connect socket.
Customer Responsibilities
Check Safety Valve
Drain Tank
automatically when
power is on. When performing
maintenance, you may be exposed
to voltage sources, compressed
air, or moving parts. Personal
injuries can occur. Before
performing any maintenance or
repair, disconnect power source
from the compressor and bleed off
all air pressure.
NOTE: See "Operation" section for
the location of controls.
MAINTENANCE
Before
each
use
Unit cycles
causes a hazardous risk of
bursting. Check the manufacturer's
maximum pressure rating for air
tools and accessories. The
regulator outlet pressure must
never exceed the maximum
pressure rating.
How to Start:
1.
Turn the On/Auto/Off lever to
"AUTO" and allow tank pressure
to build. Motor will stop when
tank pressure reaches "cut-out"
pressure.
2.
Turn regulator knob clockwise to
increase pressure and stop when
desired pressure is reached.
The compressor is ready for use.
Daily or
after
each
use
●
●
To Check Safety Valve
properly, over-pressurization may
occur, causing air tank rupture or
an explosion.
1.
Before starting compressor, pull
the ring on the safety valve to
make sure that the safety valve
operates freely. If the valve is
stuck or does not operate
smoothly, it must be replaced
with the same type of valve.
13 - ENG
Risk of Bursting. Too
much air pressure
If the safety valve
does not work
D26130