E0:
Door 1 (upper) open.
E1:
Thermistor 1 open.
E2:
Thermistor 2 open.
E3:
Thermistor 3 open.
E4:
Thermistor 4 open (Does not apply to this
model).
E5:
Thermistor 1 shorted.
E6:
Thermistor 2 shorted.
E7:
Thermistor 3 shorted.
E8:
Thermistor 4 shorted (Does not apply to
E9:
this model).
Door 2 (lower) open.
P1:
Pump Circuit open (Does not apply to this
model).
15. CLEAR ERROR LOG
To clear errors, press and hold
when CLR is flashing.
16. THERMISTOR — 1 DIFFERENTIAL
This number should not be adjusted.
17. EVAPORATOR FAN DELAY IN MINUTES —
ON
"Fan Delay On" is the amount of time in
minutes the fan will be delayed from starting
from the beginning of a cooling cycle.
Adjustable 0-99 minutes.
18. EVAPORATOR FAN DELAY IN MINUTES —
OFF
"Fan Delay Off" is the amount of time in
minutes the fan will continue to run at the end
of a cooling cycle. Adjustable 0-99 minutes.
19. INDIVIDUAL COMPONENT TOGGLE
Display #
Relay/Output
0
2
3
4
5
6
7
SEE RELAY/OUTPUT
CHART
Should be 0.
0. EXIT SERVICE MODE
Only
door
error
(5 seconds)
Exit
Relay 2
Relay 3
Relay 4
Relay 5
Relay 6
Relay 7
is
8
9
10
11
12
20. MODEL NUMBER INDICATOR
Displays the two-digit model number of the
specific unit. See model list table.
21. LIGHT ALL LED SEGMENTS
This will illuminate all the LEDs on the display
to ensure they work properly.
22. VIEW DEFROST CYCLES
Displays the number of defrosts that have
occurred in the past 24 hours.
23. VIEW COMPRESSOR RUNTIME
This will show the number of minutes the
compressor has run in the prior cycle (or
current cycle if the compressor was running
when service mode was entered).
24. ACTIVATE DEFROST/HARVEST
Turns on the hot gas bypass valve allowing
hot gas to circulate through the evaporator
causing frost to melt.
25. RESTORE FACTORY DEFAULTS
Will restore all adjustable functions to their
factory settings.
26. SOFTWARE VERSION — MAIN BOARD
Displays software version of the main control
board.
27. SOFTWARE VERSION —
Displays
interface.
28. LOG IN PERIOD
Factory use only - do not adjust.
29. FACTORY TEST MODE