Error message
Failed to register model
Memory is becoming insufficient. According to
the setting, memory shortage may occur.
Overcurrent was detected. Turn OFF the power
supply and remove the USB device to restart.
You need to format the disk in drive *: before you
can use it.
Do you want to format it?
Add to unit is failed. Insufficiency memory may
be occurred.
The free capacity of RAMDisk is insufficient.
If nothing is done, measurement cannot be
performed correctly.
Increase free capacity in RAMDisk.
Region size exceeds. Please narrow region.
Logging error
The Logon to Network Server screen is
displayed.
Vision System FH/FZ5 Series
User's Manual (Z365)
Troubleshooting
For Search, Classification, Flexible search, Shape search II
Please register higher-contrast images as models. If the model is
registered at full screen size, re-register at a smaller size.
For Fine matching
The two pixels at the edge of the image cannot be registered as the
model.
The free application memory has decreased.
Memory may become insufficient, or an error may occur in operation
mode switching.
Re-configure the inspection flow to reduce memory consumption.
The amount of memory used and free data memory can be checked from
the menu of Memory Consumption Monitor on the Measurement
Management Bar or the system menu.
Reference:
Checking the Memory Consumption and Percentage of
Memory Used (p.136) and Checking System Information [System
Information] (p.293).
• There may be a problem with the USB device.
Stop the current process and then turn OFF the Sensor Controller.
Remove the USB device and restart the Sensor Controller.
• The power consumption of the USB device may exceed the power
supply capacity of the Sensor Controller.
Stop the current process and then turn OFF the Sensor Controller.
Provide power to the USB device by using external power source, i.e.
AC adapter.
Then try to launch the Sensor Controller.
• The external memory which is inserted to the drive may have an error.
Select [Cancel] and check the external memory with your computer.
• Application memory is insufficient,
Reduce the number of processing units of measurement flow.
When you use FZ5-L / FZ5-600 series, reduce the processing type
which is registered to the measurement flow and save the system. After
that, restart the system. It may be prevent insufficiency memory.
• The amount of memory used and free data memory can be checked
from the menu of Memory Consumption Monitor on the Measurement
Management Bar or the system menu.
Reference:
Checking the Memory Consumption and Percentage of
Memory Used (p.136) and Checking System Information [System
Information] (p.293).
Clean up the content of RAMDisk to increase free space. If this error
occurs even though enough free space is available, Scene group data
may be too large. Review the inspection flow.
There are restrictions as to what can be set up based on the camera and
processing items being used. Please adjust the region size so that the
region is not too large.
Image logging failed due to insufficient memory at the save destination.
The error message disappears after 10 s. Please delete unneeded files in
the save destination or prepare a new USBDisk.
The connection was cut off based on the idling / session time set on the
network logging destination PC.
At the command prompt on the PC, enter the following:
net config server /autodisconnect:-1
Then disable the automatic disconnection setting.