Torque control
Hide thumbs Also See for TOSVERT VF-AS1:

Advertisement

3) Torque command
■ Related parameters
f420 : Torque command selection
f435 : Prohibition of rotation in any direction other than the specified one (F or R)
f201 : VI/II input point 1 setting
f203 : VI/II input point 2 setting
f210 : RR/S4 input point 1 setting
f212 : RR/S4 input point 2 setting
f216 : RX input point 1 setting
f218 : RX input point 2 setting
f222 : AI1 input point 1 setting
f224 : AI1 input point 2 setting
f725 : Operation panel torque command
• Function
Selecting a mode of torque command in torque control mode.
The command set with f420 is enabled. (Default setting: RX input)
Title
Function
Torque command
f420
selection
Note 1: Selecting 4 (panel input) activates the control panel torque reference f725.
Note 2: Use two-phase input type sensor when torque control is operated by vector control with a sensor.
Note 3: For sensorless vector control, "forward power running ⇔ reverse regeneration," and "forward
regeneration ⇔ reverse power running" cannot be operated. Use vector control with a sensor
(two-phase) for these uses.
f205 : VI/II input point 1 rate
f206 : VI/II input point 2 rate
f214 : RR/S4 input point 1 rate
f215 : RR/S4 input point 2 rate
f220 : RX input point 1 rate
f221 : RX input point 2 rate
f226 : AI1 input point 1 rate
f227 : AI1 input point 2 rate
f727 : Operation panel tension torque bias
f728 : Operation panel load sharing gain
Adjustment range
1:VI/II (voltage/current input)
2:RR/S4 (Potentiometer/voltage input)
3:RX (voltage input)
4:Operation panel input enabled
5:Communication panel RS485 input
6:Communication internal RS485 input
enabled
7:Communications option input
8:AI1 (differential current input)
6
E6581331
Default setting
3