REFRIGERANT SYSTEM DIAGRAM

ASY10FSACW / AOY10FSAC
OUTDOOR UNIT
Com-
pressor
ASY12FSACW / AOY12FSAC
OUTDOOR UNIT
Com-
pressor
2008.05.29
INDOOR UNIT
[ Connecting pipe ]
Condenser
INDOOR UNIT
[ Connecting pipe ]
Condenser
Evaporator
(Flare connection)
Gas pipe (9.52 dia.)
(Flare connection)
3-Way valve
(with charging port)
Dryer
Evaporator
(Flare connection)
Gas pipe (9.52 dia.)
(Flare connection)
3-Way valve
(with charging port)
Dryer
3
(Flare connection)
Liquid pipe (6.35 dia.)
(Flare connection)
2-Way valve
Capillary tube
(Flare connection)
Liquid pipe (6.35 dia.)
(Flare connection)
2-Way valve
Capillary tube