Plc User Alarms - Siemens SINUMERIK 808D ADVANCED Diagnostic Manual

Hide thumbs Also See for SINUMERIK 808D ADVANCED:
Table of Contents

Advertisement

SINUMERIK 808D ADVANCED alarms

3.6 PLC user alarms

Remedy:
Measurement of the individual edges shows that the specified number of edges lies outside the dimensional
difference.
A decision has to be made: whether or not one can continue working with this tool.
62377
[Channel %1: ] Block %2: Dimensional tolerance %4 exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
62500
[Channel %1: ] Block %2: GWPS has been limited
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Check limit value for GWPS and program a lower value in the NC program if necessary
62501
[Channel %1: ] Block %2: Speed has been limited
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Check limit value for speed and program a lower value in the NC program if necessary
62502
[Channel %1: ] Block %2: Dresser %4, GWPS has been limited
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Check limit value for GWPS and program a lower value in the NC program if necessary
62503
[Channel %1: ] Block %2: Dresser %4, speed has been limited
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Remedy:
Check limit value for speed and program a lower value in the NC program if necessary
3.6
PLC user alarms
700000 to 700127
For the default PLC program, refer to descriptions of PLC subroutines in the
for detailed information about the PLC user alarms.
For an machine manufacturer PLC program, refer to relevant descriptions of machine tool for detailed
information about the PLC user alarms