LG C1150 Service Manual page 54

Hide thumbs Also See for C1150:
Table of Contents

Advertisement

Checking Flow
For these 2 test case,
No Call connection is needed
Check SW301 Pin ANT,RF
with RF Cable connected.
Check SW301 Pin ANT,RF
with No RF Cable Connected
Check L304, L306
Check whether Ant SW
Set as RX mode
Refer to Table 4-1
Check RF Level of
FL301.2 (for GSM) &
FL301.11(for DCS)
Ant SW & Mobile SW is OK
See next Page to check
Rx IQ Signal
For this RF Level test case,
RX Stand alone Mode is needed
refer to chapter 11
Table 4-1
ANT SW
DCS TX
EGSM TX
EGSM,DCS RX
Open
Yes
Short
Yes
VC1 :Low
VC2 :Low
Yes
Pin1 0 : ~ -62dB m
Pin 1 : ~ -63dBm
Yes
VC1
VC2
0
1
1
0
0
0
- 55 -
4. TROUBLE SHOOTING
No
Changing SW301
No
Changing SW301
No
Changing the Board.
No
Changing FL301

Advertisement

Table of Contents
loading

Table of Contents