CIM Information
Prefix: PLAT ID: 0224
User Response
1. (Trained technician only)Reseat the microprocessor, and then restart the server.
2. (Trained technician only)Replace microprocessor n. (n = microprocessor number)
• 806f0113-0302ffff : A bus timeout has occurred on bus [SensorElementName]. (CPU 2 PECI)
This message is for the use case when an implementation has detected a Bus Timeout.
May also be shown as 806f01130302ffff or 0x806f01130302ffff
Severity
Error
Serviceable
Yes
Automatically notify support
No
Alert Category
Critical - Other
SNMP Trap ID
50
CIM Information
Prefix: PLAT ID: 0224
User Response
1. (Trained technician only)Reseat the microprocessor, and then restart the server.
2. (Trained technician only)Replace microprocessor n. (n = microprocessor number)
• 806f0123-2101ffff : Reboot of system [ComputerSystemElementName] initiated by
[WatchdogElementName]. (IPMI Watchdog)
This message is for the use case when an implementation has detected a Reboot by a Watchdog
occurred.
May also be shown as 806f01232101ffff or 0x806f01232101ffff
Severity
Info
Serviceable
No
Automatically notify support
No
Alert Category
System - Other
SNMP Trap ID
CIM Information
Prefix: PLAT ID: 0370
User Response
No action; information only.
• 806f0125-1001ffff : [ManagedElementName] detected as absent. (PCI Riser 1)
358