B: INSPECTION

1. HORN RELAY

S904436A1001
Check continuity between terminals (indicated in
table below) when terminal No. 4 is connected to
battery and terminal No. 3 is grounded.
When current
Between terminals
flows.
No. 1 and No. 2
Between terminals
No. 1 and No. 2
When current
does not flow.
Between terminals
No. 3 and No. 4
HORN SYSTEM
S904436A10
Continuity exists.
Continuity does not
exist.
Continuity exists.
S6M0048A