Filter in the case of resonance at and above the controller stability limit
Low-pass
With resonance bundle
Distribution of resonance phenomena (dependent on traversing direction, speed)
Low-pass as current setpoint filter
A low-pass filter is the better solution in cases where a peak occurs in the amplitude response
that is not linked to a fixed frequency, but wanders under different conditions. With a low-pass
filter, the signal above the entered natural frequency is damped. Reduced damping results in
less phase rotation below the natural frequency and thus to a greater phase margin.
Magnitude
[dB]
Phase
angle
Fig. 12-4