12 Functional Descriptions
12.28.8 Overview of function identifiers and configuring parameters (DB 2, DR 2 ... DR 6)
Signal
number
5
Part setpoint
6
Synchronism deviation
7
Angular offset (mech.
coupling)
8
Absolute position actual
value (without modulo
compensation)
9
Part actual value 1st
measuring system
10
Part actual value 2nd
measuring system
AXIS
100
Contour deviation
101
Abs. compensation value
SPINDLE
200
Current speed setpoint
(before ramp generator)
201
Speed setpoint (ramp
generator output)
202
Speed actual value
Explanation of digital I/O in NCK:
Function
identifier
01
The digital I/O peripherals (e.g. 6 digital inputs of Central Service Board or maximum 2 mixed
I/O modules with 2 input and output bytes each) can also be used to a limited extent in the
NCK area.
The status of these inputs/outputs can be read from the PLC by means of the high-speed data
channels. However, the outputs cannot be written from the PLC!
_______
1)
Data format
2)
Unit UMS ... Units Machine system
(0, 1) RPM ... Revolutions / minute, load-related
3)
Load speed: 400000H corresponds to 0.01% of the max. load speed
12–292
More user manuals on
Meaning
Max. permissible
Explanation
number
Digital I/O in
32
NCK
SL.. Signed Long (32 bit)
0.1 rpm when MD bit 520* bit 3 =1
1 rpm when MD bit 520* bit 3 = 0
ManualsBase.com
Data
Unit
1)
format
SL
0.01 % of max. load speed
SL
UMS
SL
UMS
SL
UMS
SL
0.01 % of max. load speed
SL
0.01 % of max. load speed
SL
UMS
SL
UMS
SL
(0.1) RPM
SL
(0.1) RPM
SL
(0.1) RPM
Parameter 1
Parameter 2
Data group
Data type
21H
© Siemens AG 1992 All Rights Reserved
09.95
Attribute
3)
Read
Read
Read
Read
3)
Read
3)
Read
Read
Read
Read
Read
Read
Parameter 3
Parameter 4
Signal
Axis/spindle
number
number
6FC5197- AA50
SINUMERIK 840C (IA)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Simodrive 611-d

Table of Contents