Notes:
S (*1): The time required for the sensor data conversion will vary depending on number of enabled
channels as follows:
S (*2): The Celsius data is expressed up to the 0.1 degree accuracy by multiplying 10 and the Celsius value
together.
Example: Temperature measured : 100 °C, Celsius data in the shared memory: K1000

3. Data Conversion Characteristics

1) Temperature range settings: 0 °C to 200 °C/32 °F to 392 °F
J Input value range vs normalized data conversion characteristics
Measured temperature (°C)
0
50
100
150
200
CH0
CH1
CH2
conversion
conversion
conversion
Conversion
time
500 ms
Conversion time
1,000 ms
Conversion time
1,500 ms
Conversion time
2,000 ms
Normalized data
0
1000
2000
3000
4000
CH3
conversion
4000
3000
2000
1000
0
0
200
400
600
Effective temperature range
2-2. Specifications
800 1000
°C