Accuracy; Led Indicators - GE Bently Nevada 1900/27 Operation And Maintenance Manual

Vibration monitor
Table of Contents

Advertisement

Frequency Response:
High Pass Corner:
Low Pass Corner:

5.1.6 Accuracy

Liquid Crystal Display
Buffered output
4 to 20 mA Interface

5.1.7 LED Indicators

OK:
Alert:
Danger:
Bypass:
Section 5 - Appendix A - Performance Specifications
3 dB corner at 8 Hz. Less than 1% error due to high
pass corner for frequency above 30 Hz.
Greater than 4 kHz. Less than 1% error due to low
pass corner for frequency below 4 kHz.
Percent of full scale range.
±3% for 30 Hz to 4 kHz
-30%, +3% for 8 to 30 Hz.
±3% for 30 Hz to 4 kHz.
-30%, +3% for 8 to 30 Hz.
±3% for 30 Hz to 1 kHz.
-30%, +3% for 8 to 30 Hz.
One constant ON green LED indicates OK condition of monitor,
transducer, and field wiring. Constant OFF indicates NOT OK
condition. OK LED flashing at 2 Hz indicates monitor has been NOT
OK, but is now OK.
One yellow LED indicates an Alert condition. Flashing at 2 Hz
indicates an Alert condition has occurred and then gone away (only
occurs if the Alert relay is configured as nonlatching).
One of the two red LEDs indicates a Danger condition. Flashing at 2
Hz indicates a Danger condition has occurred and then gone away
(only occurs if the Danger relay is configured as nonlatching).
The other red LED indicates the monitor is in BYPASS mode.