Color Purity Adjustment; Clamp Screw - Memorex MT1190C Service Manual

19”
Hide thumbs Also See for MT1190C:
Table of Contents

Advertisement

SOUND IF ADJUSTMENT
1.
Connect TV Test Pattern Generator (NTSC signal, 70dB u, channel 2) to EXT. Antenna Terminal (TE1) through
TV Channel Signal Generator. (Standard modulation is 400Hz at 25kHz deviation for sound signal.
2.
Connect positive lead of DC Digital Voltmeter to TP7 and negative lead to TP4.
3.
Adjust T203 so that the DC Digital Voltmeter reading is 4.0V.

COLOR PURITY ADJUSTMENT

For best results, it is recommended that the purity adjustment be made in the final receiver location. If the receiver
will be moved, perform this adjustment with it facing East.
The receiver must have been operating 15 minutes prior to this procedure and the face plate of the CRT must be at
room temperature. The following procedure is recommended while using a Dot/Bar Generator.
1.
Check correct location of all neck components. (Refer to Fig. 3)
2.
Rough-in the static convergence at the center of the CRT, as explained in the static convergence procedure.
3.
Set the Contrast control to minimum position and Brightness control as far maximum as possible without
causing the picture to "bloom".
4.
Apply green raster signal from Dot/Bar Generator to receiver.
5.
Loosen the deflection yoke clamp screw and pull the deflection yoke toward the rear of the CRT.
6.
Begin the following adjustment with the tabs on the round purity magnet rings set together. Slowly separate
the two tabs while at the same time rotating them to adjust for a uniform green vertical band at the center of
the CRT screen.
7.
Carefully slide the deflection yoke forward to achieve green purity (Uniform green screen).
(NOTE: Center purity is obtained by adjusting the tabs on the round purity magnet rings. Outer edge purity is
obtained by sliding the deflection yoke forward.)
8.
Check for red and blue field purity by applying red and blue raster signal alternately from Dot/Bar Generator to
receiver. Repeat steps 2 through 7, if required.
9.
Tighten deflection yoke clamp screw.
10. Perform BLACK AND WHITE ADJUSTMENT procedure.
(CW : clockwise, CCW : counterclockwise)
65.0 mm
(2.56 inches)
Fig. 3
- 7 -

CLAMP SCREW

CLAMP SCREW
6 POLE MAGNETS
4 POLE MAGNETS
PURITY MAGNETS
DEFLECTION YOKE