Overview: This installation guide provides step and step instructions 
on how to configure the RocketRAID 3G mini‐SAS storage to support 
Boot Camp. This guide also provides troubleshooting tips when 
problems occur.  
 
Part 1 – What is a Boot Camp?  
Part 2 – Pre‐requisite for Boot Camp Configuration 
Part 3 – Hardware Installation Steps and Verification Steps  
Part 4 – Software Package Installation and Verification Guide 
Part 5 ‐ Ready for the Experience  
 
 
 
 

Advertisement

loading

Summary of Contents for HighPoint RocketRAID 3G mini SAS HBA Series

  • Page 1 RocketRAID 3G mini­SAS HBA Series Boot Camp  Installation Guide.    Overview: This installation guide provides step and step instructions  on how to configure the RocketRAID 3G mini‐SAS storage to support  Boot Camp. This guide also provides troubleshooting tips when  problems occur.     Part 1 – What is a Boot Camp?   Part 2 – Pre‐requisite for Boot Camp Configuration  Part 3 – Hardware Installation Steps and Verification Steps   Part 4 – Software Package Installation and Verification Guide  Part 5 ‐ Ready for the Experience          ...
  • Page 2                   Part 1 – What is a Boot Camp?  Boot Camp is software included with Mac OS X 10.5 Leopard that lets you run  compatible versions of Microsoft Windows on an Intel‐based Mac. Boot Camp 4.0 is  the latest version of Boot Camp. You can use Microsoft Windows 7 Home Premium,  Microsoft Windows 7 Professional, or Microsoft Windows 7 Ultimate with Boot  Camp. 64‐bit versions of Windows 7 are supported.   Note: Boot Camp releases before 4.0 support 32 and 64‐bit releases of Windows  Vista.          ...
  • Page 3                                   Part 2 – Pre­requisite for Boot Camp Configuration  System Requirements  Mac Hardware: Intel‐based Mac with an available PCIe 2.0 or 1.0 slot capable of  supporting an x8 (8‐lane) length PCIe card. For optimal performance, at least use a  PCIe 1.0 slot running at x8 speeds or greater.   Slot recommendations for the RocketRAID 3G mini‐SAS series controller.   Mac Pro Model   Core / CPU Speed GHz  EFI   Slot Number  2006  Quad Core / 2.0, 2.66, 3.0  32‐bit  3,4  2006  Eight Core /3.0  32‐bit  3,4  2008  Quad Core / 2.8  64‐bit  2,3,4 ...
  • Page 4 2008  Eight Core/ 2.8, 3.0, 3.2  64‐bit  2,3,4   2009  Quad Core / 2.66/2.93/3.33 64‐bit  2,3,4  2009  Eight Core / 2.26, 2.66, 2.93  64‐bit  2,3,4  2010  Quad Core / 2.9, 3.2  64‐bit  2,3,4   2010  Six Core / 3.3  64‐bit  2,3,4  2010  Eight Core / 2.4  64‐bit  2,3,4   2010  Twelve Core / 2.66, 2.93  64‐bit  2,3,4    Operating System: Mac OS X 10.5.x, 10.6.x, and 10.7.x   Hardware Installation   Before, installing the RocketRAID 3G mini‐SAS series controller make sure the  computer is turned off and unplugged from its power source. Take appropriate  electrostatic discharge precautions:  Your computer is a static‐sensitive device. It is susceptible to invisible damage if not  protected during installation.  We recommend proper grounding by using a grounding strap. Make sure to work in  a clean and static‐free area, and avoid wearing clothing that retains static charges.       ...
  • Page 5 space, speed, data protection, or any combination of the three. The RocketRAID 3G  mini‐SAS series controller supports the following RAID types:  RAID 0 “Stripe”  Speed: Data is alternated across two or more drives to gain speed by essentially  distributing the workload.
  Protection: No built‐in protection.  Capacity: Usable space is the combined capacity of all the drives.  RAID 5 “Stripe & Protection”  Speed: Data is striped like in a RAID 0, so significant speed gains are seen. 
  Protection: Utilizes mathematical parity to achieve data protection while taking up  a minimum of space. One drive can fail and all data will still be accessible.  Capacity: All but one drive worth of capacity is usable. Minimum three drives are  needed to create a RAID 5 array. In a three drive RAID 5 array, there is two drives  worth of usable space.  RAID 6 “Enhanced RAID5”  Speed: Data is striped like in a RAID 0, so significant speed gains are seen. 
  Protection: Utilizes mathematical parity to achieve data protection while taking up  a minimum of space. Two drives can fail and all data will still be accessible.  Capacity: All but two drives worth of capacity is usable. Minimum four drives are  needed to create a RAID 6 array. In a four drives RAID 6 array, there is two drives  worth of usable space.    Combined RAIDs: RAID 10/50  Speed: Combines multiple RAID 1 or RAID 5 sets by using RAID 0 “Striping” to gain  speed. 
  Protection: There are two RAID 1 or 5 “Mirrored” sets used in order to tolerate 1‐2  drives failing depending on which drives they are.  ...
  • Page 6 Capacity: For RAID 10 its usable space is half of the combined capacity of all the  drives used,while for RAID 50 its usable space is each RAID5 capacity*RAID5  number.    RAID 1 “Mirror”  Speed: No speed benefits gained. 
  Protection: One drive can fail and all data will still be accessible.   Capacity: One drive worth of usable space out of the two total drives used.  JBOD (Independent Drive Modes)  Speed: No significant speed gains. 
  Protection: No built‐in data protection. 
  Capacity: In JBOD mode, the capacities are combined. When set up as independent  drives, each drive presents its stated capacity for use.                       ...
  • Page 7                       Part 3 ­ Hardware Installation Steps and Verification Steps   Before installing the RocketRAID 3G mini‐SAS series controller   • Make sure computer is turned off and unplugged from its power source   • Take appropriate electrostatic discharge precautions:.  Remove the PCIe slot cover.  Gently insert the RocketRAID 3G mini‐SAS series controller into the PCIe slot and  secure the bracket to the computer chassis according to your chassis specifications.  After installing the RocketRAID 3G mini‐SAS series controller, start your computer.             ...
  • Page 8                           Part 4 ­ Software Package Installation and Verification Guide   Installing Boot Camp  Use the Mac OS X Boot Camp Assistant to prepare your hard drive for a fresh  Windows installation.   ...
  • Page 9: Driver Installation

        Once the Windows installation finishes you will need to install the Windows driver  for the RocketRAID 3G mini‐SAS series controller.   Boot up into Windows and follow the driver installation procedure for the  RocketRAID 3G mini‐SAS series controller.             Driver Installation   The RocketRAID 3G mini‐SAS series controller Windows drivers are available on the  http://www.highpoint‐tech.com. ...
  • Page 10: Driver Verification

    Windows 7 (Versions)  Once you have installed the RocketRAID 3G mini‐SAS series controller and  downloaded the software package, boot into Windows and follow these instructions  to install the device drivers:  1. Go to Control Panel and navigate to Device Manager   2. Double‐click on the entry RAID Controllers  3. Follow the on‐screen steps to complete the installation and you will be prompted  to restart your Mac Pro system.   Driver Verification   Verify that the driver has installed correctly by following these steps.   1. Go to Control Panel and navigate to Device Manager   2. Right‐click on the entry SCSI and RAID Controllers and select the property item.  3. You should see the entry for the RocketRAID 3G mini‐SAS series controller                  ...
  • Page 11: Software Installation

          Part 5 ­ Ready for the Experience  Software Installation   Once the driver verification has passed, you can proceed to install the HighPoint  RAID management web GUI. The Window web GUI can be downloaded from the  HighPoint website http://www.highpoint‐tech.com/, look for the product  RocketRAID 4322.   Log into web GUI   Once the Windows web GUI is installed you can enter the web GUI to create a RAID  array or manage the storage attached to the RocketRAID 3G mini‐SAS series  controller.   Log into the web GUI by entering opening a browser and entering the following URL  http://localhost:7412  User Name: RAID   Password: hpt    Troubleshooting Tip: If you are not able to login to the URL, please check previous  troubleshooting steps to verify that the driver is install and that the RocketRAID 3G  mini‐SAS series controller is detected. ...
  • Page 12   Once you have successfully logged into the web GUI, you can create any supported  RAID array or check any of the HDD attributes.     Note: Any single HDD attached to the RocketRAID 3G mini‐SAS series controller will  be detected automatically. ...