EnGenius ECB350 User Manual page 37

11n long range multi-function gigabit client bridge
Hide thumbs Also See for ECB350:
Table of Contents

Advertisement

36
Select PPTP to begin configuration of the PPTP connection.
Internet Connection Type
Specify the Maximum Transmit Unit size. It is recommended you accept the default setting of
MTU
Auto. Otherwise, packets will be fragmented downstream if the MTU is set too high or too low,
which impacts network performance. In extreme cases, an MTU setting that is too low can
prevent the ECB350 from establishing some connections.
Enter the WAN port IP address.
IP Address
Enter the WAN IP subnet mask.
Subnet Mask
Enter the WAN gateway IP address.
Default Gateway
Enter the IP address of the PPTP server.
PPTP Server
Enter the Username provided by your ISP.
Username
Enter the Password provided by your ISP.
Password
Enter the Service Name provided by your ISP.
Service Name
Select the radio button to specify the maximum idle time. Internet connection will disconnect
Connect on Demand
when it reach the maximum idle time, but it will automatically connect when user tries to access
the network.
Select whether to keep the Internet connection always on, or enter a redial period once the
Keep Alive
internet lose connection.
Click this radio button to obtain the DNS automatically from the DHCP server.
Get Automatically From ISP
Click the radio button to set up the Primary DNS and Secondary DNS servers manually.
Use These DNS Servers
Check to Enable to recognize pings on the ECB350 WAN interface or Disable to block pings on
Discard Ping on WAN
the ECB350 WAN interface. Note: Pinging IP addresses is a common method used by hackers
to test whether the IP address is valid. Blocking pings provides some extra security from
hackers.
Click Accept to confirm the changes or Cancel to cancel and return previous settings.
Accept / Cancel

Advertisement