Specifications; Physical And Environmental Ratings; Electric Service Ratings; E-Stop Precaution - Stanley QB Expert Instruction Manual

Table of Contents

Advertisement

1.6

Specifications

1.6.1 Physical and Environmental Ratings

Operating Conditions:
Ingress Protection Rating: IP54

1.6.2 Electric Service Ratings

These are the minimum electric service ratings for the QB Expert Alpha controller and the tools it can control.
Current for Supply Voltage:
* 200−240V AC highly recommended

1.6.3 E-Stop Precaution

INTEGRATED E-STOP CIRCUIT NOT PRESENT
To Avoid Injury:
• When a QB Expert Alpha controller connects to a tool where a fault can result in personal injury or substantial
damage to property, an E-stop circuit is required. An E-stop circuit must be created in the external electrical
service supply line.

1.6.4 Tool Speed and Torque Scatter Versus Electric Supply

The minimum electric supply voltage required to attain catalog speeds is 104V AC or 208V AC depending which
supply voltage system is used. Supply voltages above these minimums should have NO effect on reducing speed.
Supply voltages BELOW these minimums will reduce maximum free speed proportionally; actual speed should be
the LOWER of the speed command or the maximum attainable speed. Slow Seek and downshift speeds should
not be affected unless they are set close to maximum attainable speed. Similarly torque scatter should NOT be
affected by reduced supply voltages.

1.6.5 Tool Temperature Versus Electric Supply

Supply voltages that remain within recommended limits during the fastening cycle will provide shortest cycle
times and lowest tool temperatures. Tool temperatures on applications with moderate to high prevailing torque
levels and/or low (i.e. soft) torque rates stand the most chance of being negatively impacted by low or "sagging"
Instruction Manual
Width:
Dimensions:
Height:
Depth:
Weight:
Temperature: 32 to 122 ºF (0 to +50 ºC)
Humidity:
Tool Model:
100 − 126.5V AC
200 − 253V AC
Standby
Power Consumption:
Continuous
6.0 inches
152 mm
16.0 inches
406 mm
10.4 inches
264 mm
18 pounds
8.2 kgrams
0 to 95 % non-condensing
NEMA 3
E02-E23
E33-E34
EA23
EA33−EA34
EB02−EB22
EB33-EB34
EC02−EC22
EC33-EC34
15 A
15 A
10 A
10 A
0.2 A
0.2 A
0.3 kVA
0.7 kVA
WARNING
Introduction
E44-E45
E55
EB44-EB45
EB55
EC44
20 A *
30 A *
10 A
10 A
0.2 A
0.2 A
1.0kVA
2.2 kVA
11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents