Specifications - Fujitsu ARY90ELA3 Service Manual

Duct type, indoor/outdoor units
Table of Contents

Advertisement

INDOOR UNIT
OUTDOOR UNIT
COOLING CAPACITY
HEATING CAPACITY
ELECTRICAL DATA
POWER SOURCE
FREQUENCY
RUNNING CURRENT
(A)
INPUT WATTS
(kW)
EER
(kW/kW)
MOISTURE REMOVAL
AIR CIRCULATION-Hi
COMPRESSOR
TYPE
CODE
REFRIGERANT
(R407C)
FAN MOTOR
MODEL NO.
TYPE
POWER SOURCE
HI-SPEED
LO-SPEED
DIMENSIONS
H x W x D
WEIGHTS
GROSS / NET
ADDITIONAL REFRIGERANT CHARGE
PIPE LENGTH
FULL CHARGE AMOUNT
Note :
• Between 30 m and 50 m, when using a connection pipe other than that in the table,
charge additional refrigerant with 100 g/1 m as the criteria.
• The above list shows values at the external static pressure of 20 mm Aq. (196 Pa).
S P E C I F I C A T I O N S
ARY90ELA3
AOY90EPB3L
(kW)
24,8 - 25.4
(kW)
(V)
(Hz)
COOLING
19.5 - 19.5
HEATING
COOLING
12.2 - 12.5
HEATING
COOLING
2.03 - 2.03
HEATING
(R/hr)
(m
3
/hr)
Hermetic type, 2 pole, 3-phase, Induction motor
(g)
ARY90ELA3
MFA-90GQH
(V)
380 - 415
(r.p.m.)
(r.p.m.)
(mm)
450 x 1,550 x 700
(kg)
30m
7,000g
– 1 –
––––
415
50
––––
––––
––––
7.5
4,300
ZRT122K3E-TFD
7,000
ARY90TLA3
AOY90EPB3L
1,140
––––
1,380 x 1,300 x 650
100 / 85
280 / 243
40m
8,000g
ARY90TLA3
AOY90TPB3L
24,8 - 25.4
28.9 - 29.5
19.5 - 19.5
19.5 - 19.5
12.2 - 12.5
12.2 - 12.5
2.03 - 2.03
2.36 - 2.36
AOY90TPB3L
MFB-90FTH
220 - 240
730
360
282 / 245
50m
9,000g

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ary90tla3Aoy90tpb3lAoy90epb3l