Circuit Description - Kenwood RXD-M33V Service Manual

Mini hifi component system
Table of Contents

Advertisement

1. Initializing
1-1 Initialization Method
• While pressing the [POWER] key, turn the AC on.
1-2 Initialization Operation
• During the initial operation, the display shows "INI-
TIALIZE" and after that it will be returned to standby
condition.
• If any mechanisms error occurred, the error indication
is displayed as "ERR" in the display.
1-3 Mechanism Initializations
1 CD Mechanism
• If a mechanism error occurred, the error indication is
displayed as "C ERR" in the display.
2 Deck Mechanism
• If a mechanism error occurred, the error indication is
displayed as "X ERR" in the display.
2. Tuner Destination
Destin-
Receiving Frequency Channel
Set
Band
ation
Range
M
K2
FM
87.5MHz~108.0MHz
AM
530kHz~1610kHz
3. Tuner Preset Frequency
Frequency
P.CH
M,M2,I Type
1
FM 98.30MHz
2
FM 98.00MHz
3
FM 87.50MHz
4
FM 89.10MHz
5
FM 108.0MHz
6
FM 90.00MHz
7
FM 87.50MHz
8
FM 87.50MHz
9
AM 1602kHz
10
AM
999kHz
11
AM
630kHz
12
AM 1440kHz
13
FM 106.0MHz
14
AM
531kHz
15
FM 87.50MHz
16
FM 98.00MHz
17
FM 98.50MHz
18
FM 87.50MHz
19
AM
990kHz
20
FM 97.70MHz

CIRCUIT DESCRIPTION

IF
RF
Space
100kHz
+10.7MHz 25kHz
10kHz
+450kHz
10kHz
K2(M,M2 Type)
FM 98.30MHz
FM 87.50MHz
FM 89.10MHz
FM 108.0MHz
FM 90.00MHz
FM 87.50MHz
FM 87.50MHz
FM 87.50MHz
AM 1610kHz
AM 1000kHz
AM
630kHz
AM 1440kHz
FM 106.0MHz
AM
530kHz
FM 87.50MHz
FM 98.00MHz
FM 98.50MHz
FM 87.50MHz
AM
990kHz
FM 97.40MHz
RXD-M33V
Frequency
P.CH
M,M2,I Type
21
AM 531kHz
22
FM 87.50MHz
23
FM 87.50MHz
24
FM 87.50MHz
25
FM 87.50MHz
26
FM 87.50MHz
27
FM 87.50MHz
28
FM 87.50MHz
29
FM 87.50MHz
30
FM 106.0MHz
4. Test Mode
4-1 Setting method of the Test Mode
• While pressing the "below each" key in the table, turn
the power switch on.
TEST MODE
CD MODE
CD PLAY key+AC ON
DECK MODE
TAPE PLAY key (3) +AC ON
FCT & SUB CLOCK
MENU key + AC ON
OSC DIAGNOSIS
The oscillation diagnosis (existence of oscillation and
measurement of period) of a sub clock is performed
before the test mode is entered. If the diagnosis
result is OK, the system enters the test mode.
If the diagnosis result is NG, the oscillation of the sub
clock is diagnosed again. If the result is OK, the sys-
tem enters the test mode. If the diagnosis result is
continuously NG 5 times, the system stops with
"ERR1" and "ERR2" displayed.
4-2 Cancel of the test mode
• By turning the AC off, the system is initialized and
the test mode is canceled.
• Cancel the test mode only if the power switch is
turned off.
4-3 Contents of the Test Mode
• The muting during mode selection is not controlled
in the test mode.
• During the test mode, it can be operated in a special
manner that is different from an ordinary operation
by using the keys on the main body, specifically as
shown in the following tables.
K2(M,M2 Type)
AM 530kHz
FM 87.50MHz
FM 87.50MHz
FM 87.50MHz
FM 87.50MHz
FM 87.50MHz
FM 87.50MHz
FM 87.50MHz
FM 87.50MHz
FM 106.0MHz
SETTING METHOD
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents