This section covers unpacking and inspection, identification of LOOSE-SHIPPED PARTS, selecting location,
installing Unit, preparing Unit for operation, and Unit operation.

UNPACKING AND INSPECTION

(see Figure 4)
NOTE: The Unit was thoroughly inspected before leaving the factory and the carrier has accepted and
signed for it. Any damage or irregularities should be noted at time of delivery (or not later than 15 days
from date of delivery) and immediately reported to the delivering carrier. Request a written inspection
report from Claims Inspector to substantiate any necessary claim. File claim with the delivering carrier,
not with IMI Cornelius Inc.
1. After Unit has been unpacked, remove shipping tape and other packing material.
2. Remove hood by loosening screw on top of hood until screw disengages from drop-in refrigeration
assembly, then lift hood up off Unit.
3. Unpack LOOSE-SHIPPED PARTS. Make sure all items are present and in good condition.
Item
No.
Part No.
1
4537
Drip Tray
2
4547
Cup Rest
3
317904XXX
Flavor Decal Kit
4
151741039
Knob, Dispensing Valve

IDENTIFICATION OF LOOSE-SHIPPED PARTS

(see Figure 4)
1. DRIP TRAY (item 1) to be installed on the Unit, then CUP REST (item 2) to be installed in the drip tray.
2. Individual flavor decals included in the FLAVOR DECAL KIT (item 3) are to be installed on the
DISPENSING VALVES KNOBS (item 4), then knobs are to be installed on the dispensing valves .

SELECTING LOCATION

DANGER: To avoid possible fatal electrical shock or serious injury to the operator, it is
highly recommended that a GFCI (ground fault circuit interrupt) be installed in the
electrical circuit for the domestic Units. It is required that an ELCB (earth leakage circuit
breaker) be installed in the electrical circuit for the export Units
This Unit may be island-mounted or installed on a front or rear counter. Locate the Unit so the following
requirements are satisfied.
1. The Unit must be installed near a properly grounded electrical outlet with proper electrical requirements.
The electrical circuit should be fused at 20-amps (" slow-blow" ) or circuit must be connected through an
equivalent HACR circuit breaker.The electrical outlet must be accessible for ease of connecting and
disconnecting the Unit power cord from the outlet. No other electrical equipment should be connected to
this circuit. ALL ELECTRICAL WIRING MUST CONFORM TO NATIONAL AND LOCAL ELECTRICAL
CODES.

INSTALLATION

Table 2. Loose-Shipped Parts

Name
7
Qty.
4-fl 5-fl
1
1
1
1
1
1
4
5
5600001790