IMPORTANT SAFETY INFORMATION ............................1 I. INSTALLATION INSTRUCTIONS ..............................3 1. UNPACKING ..................................3 2. LOCATION ...................................3 3. INSTALLATION ..................................4 [a] STORAGE BIN ................................4 [b] MULTI COMPRESSOR RACK SYSTEM ........................4 [c] LIQUID AND SUCTION LINES ............................5 4. ELECTRICAL CONNECTIONS ............................6 5. WATER SUPPLY AND DRAIN CONNECTIONS .........................6 II.
ENGLISH IMPORTANT SAFETY INFORMATION Throughout this manual, notices appear to bring your attention to situations which could result in death, serious injury, or damage to the unit. Indicates a hazardous situation which, if not avoided, could result in WARNING death or serious injury. Indicates a hazardous situation which, if not avoided, could result in CAUTION minor or moderate injury.
Page 4
* If the supply cord is damaged, it must be replaced by a replacement cord available from Hoshizaki Parts/Service Centres. * Do not touch the electrical parts or operate the switches with damp hands. * This appliance is not intended for use by persons (including children) with reduced...
T h e r e c o m m e n d e d s t o r a g e b i n i s the contents: HOSHIZAKI ICE STORAGE BIN, model B-300SD(PD) or B-500SD(PD) with top kit Mounting Bracket...
Use an appropriate condensing unit such as: 4) Pull down the end of the string coming out of the chute opening to remove the cushion. FM-1200ALKE(-N) OP-LCHC096NTA02 by DANFOSS Note: If the power supply is turned on with the Evaporating temperature: -25°C 3560W cushion left inside, the icemaker will not start showing “BIN FULL”...
ENGLISH When the condensing unit operates for more than 2) To e n s u r e t h e m o s t e ff i c i e n t i c e m a k i n g one icemaker, install a ball valve on the liquid line capacity (10/10°C), set the icemaker as below.
* Supply of replacement fuse covers can be compressor pumping down. obtained from Hoshizaki Parts/Service Centres. 2) After completing all the refrigeration tubing * The wires in the mains lead are coloured in...
Page 9
Tap Washer of an external filter or softener is recommended. Contact your local water treatment professional or Hoshizaki service agent. Braided SS * Water supply pressure should be minimum 0.05 Inlet Hose MPa (0.5 bar) and maximum 0.8 MPa (8 bar).
ENGLISH 2. SHUT DOWN II. OPERATING INSTRUCTIONS Push the stop button on the operation panel. WARNING The display will blink in the “STOP” mode for 15 1. This icemaker is designed to produce and minutes during the drain control operation and will store edible ice.
Hoshizaki warrants to the original owner/user that Gear motor failure. Turn OFF operation switch, and turn all Hoshizaki branded products shall be free of it ON again. If error code appears again, call for service. Supply voltage is too low. Check that voltage is in...
Page 13
ENGLISH Model FM-1800ALKE FM-1800ALKE-N Type Air-cooled, flake ice Air-cooled, nugget ice Power Supply 1 phase 220 - 240V 1 phase 220 - 240V 50Hz 50Hz Electric 710W 770W Consumption (AT: 10°C, WT: 10°C) (AT: 10°C, WT: 10°C) Ice Production 1800kg 1590kg per 24h (AT: 10°C, WT: 10°C) (AT: 10°C, WT: 10°C) Dimensions...