Yamaha R-S300 Service Manual page 59

Hide thumbs Also See for R-S300:
Table of Contents

Advertisement

A
B
C
MAIN
1
Destination Part List
sXX
LOC
UC
R
s101
TE101
WU98700
WU98700
MST-224VD-03
MST-224VD-03
s102
TE102
WU98690
WU98690
2
MST-224VD-02
MST-224VD-02
s103
C153
X
X
C154
C156
C157
C158
C159
s104
C150
WJ61140
WJ61100
C151
0.1/100 (J)
0.047/100
s120
C115
UR27833
UR27833
330/63
330/63
s121
C124
UR26747
UR26747
C127
47/50
47/50
s122
C133
UR81810
UR81810
100/6.3
100/6.3
s123
C155
X
X
s124
C167
US163100
US163100
1000P/50
1000P/50
3
4
0
0
0
W105
Page 57
J8
to OPERATION (6)_CB706
5
37.7
6
37.1
0.7
0.7
0.7
0
0
-44.8
-45.6
7
OUT L
CB101
0
0
0
0
8
Page 57
E5
to OPERATION (2)_W803
-44.8
-45.6
0
0
0.7
0.7
9
0.7
37.2
37.8
10
D
E
F
IC101: LM61CIZ
Temperature sensor
A
G
L
WU98700
WU98720
WU98720
MST-224VD-03
MST-224VD-03
MST-224VD-03
WU98690
WU98710
WU98710
MST-224VD-02
MST-224VD-02
MST-224VD-02
WN16530
WJ61020
WN16530
0.01/100
0.01/100
0.01/100
WJ61100
WJ61080
WJ61100
0.047/100
0.033/100
0.047/100
UR27833
UR07847
UR27833
330/63
470/63
330/63
UR26747
UR34810
UR26747
47/50
100/25
47/50
UR81810
UR03810
UR81810
100/6.3
100/16
100/6.3
X
WJ60890
X
1000P/100
US163100
X
US163100
1000P/50
1000P/50
46.2
46.2
37.1
1.2
0.6
1.2
1.2
-0.3
-1.0
-1.0
-0.4
-1.0
-1.0
-46.2
-44.8
-45.4
-45.4
-44.8
-46.2
-1.0
-1.0
-0.4
-1.0
-1.1
-0.3
1.1
1.1
0.6
1.1
46.2
37.8
46.2
Note) Those parts marked with "#" are not included in the P.C.B. ass'y.
G
H
Notes)
Safety measures
IC102: NJM4580E
Dual operational amplifier
V+
8
2, 6
1, 7
OUTPUT
–INPUT
+INPUT
3, 5
V–
4
MAIN (3)
5 k-ohms
46.2
46.1
0
46.2
0.6
#
45.9
0
0
0
0
0
0
-0.4
#
0
0
-46.2
0
0
-46.2
0
0
-0.4
#
0
0
0
0
45.9
0.6
#
46.2
MAIN (1)
5.0
0
1.0
MAIN (2)
I
J
K
Page 58
to OPERATION (13)_CB26
26.5
26.5
29.4
0.3
0.3
29.4
0.3
0.3
29.4
5.0
5.0
0
0
0
0
10 W
5 k-ohms
10 W
-15.5
SUBWOOFER OUT
0
0
0
0
5.0
1.0
0
15.5
-15.5
0
0
OUT L
0
5.0
1.0
W102
W104
Page 55
L4
Page 57
F4
to FUNCTION (1)_CB506
to OPERATION (2)_CB805
L
M
N
R-S300
G2
W103
-26.2
0.2
29.4
-0.4
AC67.3
CB105
to POWER TRANSFORMER
46.2
(34.5)
AC50.6
0
0
-46.2
(-34.5)
LOW
HIGH
IMPEDANCE
SELECTOR
A
B
SPEAKERS
A
B
POWER
ON/OFF
MANAGEMENT
0
0
OUT
SUBWOOFER
-15.5
0
0
★ All voltages are measured with a 10MΩ/V DC electronic voltmeter.
★ Components having special characteristics are marked
and must be replaced
with parts having specifications equal to those originally installed.
★ Schematic diagram is subject to change without notice.
59