Table 13 Ita-81A Traffic Display Leading Particulars - Honeywell CAS-100 Maintenance Manual

Collision avoidance system
Table of Contents

Advertisement

Table 13. ITA-81A Traffic Display Leading Particulars
Characteristic
Maximum Weight
Overall Dimensions
Mounting
Power Input Requirements
Operating Temperature Range
Cooling
Type of Display
Scan Rate
Inputs from TCAS
Output to TCAS
Electrical Connector
Environmental Certification
Use or disclosure of information on this page is subject to the restrictions in the proprietary notice of this document.
MAINTENANCE MANUAL
CAS-100 COLLISION AVOIDANCE SYSTEM
8 lb (3.7 kg)
See Outline Drawing, Figure 2014.
Dzus Mounting
115 V, 400 Hz, 35 W nominal
-15C to +55C
Convection (forced-air cooling not required)
Rectangular CRT, X-Y scan
65 Hz
High-speed ARINC 429
Display Enable (grounded input enables unit's power supply)
Display Valid (ground = valid, open = failure)
MS-3120E-14-19P (ITT Cannon KPT02-14-19P)
Refer to Table 14.
Description
34-45-47
Page 35
1 Dec 2003

Hide quick links: