Seiko 5T82A Technical Manual page 21

Advertisement

PROCESS
SPECIFICATIONS (QUALITY SPECIFICATIONS,
No.
Pull out the crown temporarily to the first click position when removing
Remove the
the winding stem.
43
winding stem.
Set the movement
Remove dust and dirt on the movement with dial and hands and inside of
with dial and
the case before casing
hands into the case.
Set the winding
43
stem.
Set the buttons.
*1 Only some models require this process. Whether a watch requires this
1
(2 pieces)
process or not depends on the design of its case.
Set the antimagnetic
Make sure that it is securely set in the correct direction.
10
shield plate B.
Close the case
back.
Cal. 5T8 2 A TEC HNICA L GU IDE
HANDLING METHODS ETC.)
ILLUSTRATIONS AND SPECIAL INSTRUCTIONS ETC.
43
Be careful so as not to deform the winding stem conducting spring of the circuit block cover while
removing or installing the winding stem.
43
Set the winding stem.
For a watch with a screw lock type crown, apply silicone grease (100,000 to 500,000 c.s.) to the point
of contact between the winding stem and gasket of the crown.
A sufficient amount of silicone should be applied so that the entire surface becomes wet. (See the
illustration below.)
10 Set the anti magnetic shield plate B.
Close the case back.
Make sure that the circuit block cover is securely hooked before closing the case back.